Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
Services
Fault finding, the board, residual current, rewiring, lighting, sockets, earth, an air-conditioner circuit, the intercom, an office, cable and vehicle charging. Each card has one page.


Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
From the field
Emergency van · +90 582 403 10 87The card name is the job. The safety steps and the 2026 price band sit on that page.
Electrical fault findingA burning smell, a breaker that will not hold, a dark flat. The price is not locked before the measurement.Breaker and board faultsThe lever is not forced. The same amp rating goes back.Leakage findingA 30 mA device is not bridged. Leakage is split circuit by circuit.Rewiring and refitAn old flat, a new flat, and the riser. A joint is not buried in plaster.Lighting, chandelier and spotsA heavy chandelier is hung from concrete. A flickering LED is a loose neutral or a hot driver.Socket and switch faultsA burnt, hot, or loose socket. A melted body is replaced.EarthingA water pipe is not an earth. A socket is not called earthed before the tail is measured.Air-conditioner circuitThe air conditioner and the built-in oven get their own circuit. A shared socket drops the breaker on start.Bell and intercomA silent bell and a video intercom. The door circuit is not left on the flat's socket.Office and shop wiringA shop, an office, and a counter. A metal body is not left without earth.Cable and new circuitsAn NYM run, jointed in the box. The joint does not disappear inside the wall.Vehicle chargerThe charger is written as its own circuit and a board calculation. It is not plugged into a shared socket.Choose a district. The on-call crew stands on the Anatolian side and in Bağcılar. The other districts stay in the index. The same text is not copied onto them.
Arnavutköy electricianAvcılar electricianBağcılar electricianOn callBahçelievler electricianBakırköy electricianBaşakşehir electricianBayrampaşa electricianBeşiktaş electricianBeylikdüzü electricianBeyoğlu electricianBüyükçekmece electricianÇatalca electricianEsenler electricianEsenyurt electricianEyüpsultan electricianFatih electricianGaziosmanpaşa electricianGüngören electricianKağıthane electricianKüçükçekmece electricianSarıyer electricianSilivri electricianŞişli electricianSultangazi electricianZeytinburnu electrician
A loose screw connection has carbonised the terminal. Take that outlet out of service at once; the point is found with a thermal camera without opening the wall.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
Branches are separated one by one at the board and the device reset; if it holds the fault is in the wiring, if not it is the device. The faulty leg is confirmed with a megohmmeter.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
If the building is dark, the record belongs to 186. If only the flat is dark, the fault is after the meter: one phase is missing or the neutral has broken. On neutral loss one phase climbs above 250 volts and another falls to 180.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
Inrush exceeds the existing circuit. The fix is not a bigger breaker but a dedicated run from the board with a motor characteristic device.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
The chandelier is fixed to the existing box and a load-rated hook. If the hook is not anchored in the slab, it is not hung. Live, neutral and earth are confirmed separately; the body is never put on phase.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
There is no protective earth and the neutral is bridged to the earth terminal in the socket. This is a lethal risk; stop using the appliance immediately.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceThe bands below are the labour ranges actually seen on recent call-outs and exclude materials. The binding figure is given in writing after on-site measurement, and no work starts without approval.
| Job | Typical price range | What is included |
|---|---|---|
| Fault diagnosis and measured survey | 750 TRY – 1,500 TRY | Diagnosis with a True-RMS clamp, megohmmeter and thermal camera; the survey fee is deducted if the repair is accepted. |
| Breaker / RCD replacement | 1,250 TRY – 3,200 TRY | A 30 mA Type A device; varies with the number of ways and whether Schneider or Siemens is specified. |
| Dedicated air conditioning circuit | 2,400 TRY – 5,500 TRY | 3x2.5 or 3x4 mm² solid copper with a C20-C25 breaker; varies with run length and trunking route. |
| Flat board renewal (modular DIN) | 6,500 TRY – 16,000 TRY | Varies with room count, circuit splitting and whether a surge arrester is included. |
| Chandelier, spot and socket installation | 650 TRY – 2,800 TRY | Priced per unit; heavy chandeliers include a steel anchor set into structural concrete. |
| Internet and Cat6 data cabling | 1,100 TRY – 4,200 TRY | Includes a Cat6 run per room, an RJ45 data outlet and verification with a cable tester. |
| Factory / power factor periodic maintenance | 4,500 TRY – 18,000 TRY | By panel and step count; includes a thermal sweep and a written measurement report. |
Prices are estimated labour ranges and exclude materials. A binding quote is issued in writing after the technician measures on site and before any work begins. Last updated: October 2026.
MYK-certified master application
ElektrikçiGO is not a listing and not a technician network. The job runs on the founder's expert line. If you hold an MYK certificate and work from the Pendik hub, fill in the form. Dispatch takes the call; the person who attends does the measurement.
Open the application form