An electrician in Çatalca does not go to a factory board. The call comes from a detached house toward Karacaköy, Çiftlikköy, İnceğiz and Karamandere. The house's water is in the well. When the well motor stops, the house is left without water. The part that stops the motor is often the starter: the contactor and the thermal overload. That is electrical work. The thermal is not silenced by turning it above the nameplate current. The long rural run is NYY. NYM does not enter field soil. The house's outdoor board loses its gasket in the rain and damp sticks the coil. If the whole village is dark and the meter is cold, the report belongs to BEDAŞ. The seal is not opened. If the house is lit and the motor is silent, the fault is in the starter after the meter. Distance is written in the appointment book. A house without water is not turned into a minute sentence. The slot is said before setting off.


Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
From the field
Emergency van · +90 582 403 10 87
The tank of a detached house depends on the well motor. When the motor is silent the tap is silent. The caller takes this for a mains fault. If the house lamp is on, the mains is there in that house. The place to look is the starter. If the contactor coil does not pull, the motor does not turn. If the coil stays stuck, the motor hums when it should have stopped. If the contact face is burnt, one phase goes, the motor groans on two phases, and the thermal trips. A thermal that has tripped is not counted as having solved the fault. What solves it is writing with the clamp which phase is missing. The three phases are read separately. If one is absent, the cable, the fuse or a burnt contact is hunted. If all three are there and the current is above the nameplate, the shaft is being forced or the well is spinning dry. The thermal is not raised then. A raised thermal does not protect the winding. It waits for the winding to burn. The house is still without water, and the motor burns as well. The starter is electrical work. A mechanical repair of the pump impeller is not this visit's claim. The claim is to read the contactor and the thermal, and to see that the motor body is bonded to the earth bar.
The nameplate current is written on the motor body. The thermal dial is not taken above that number. It is not dropped so low that it trips at once on starting either. The setting is compared with the clamp reading. The reading is not an idle measurement in the air. It is written while the motor is pumping water, close to the tank being full. The starting moment is a separate line, and the running current is a separate line. If they are mixed, the thermal is raised because it trips on starting, and the strain in the running current stays unseen. The brand of the contactor is not the subject of the conversation. Even if the body is Schneider or Siemens, the coil voltage and the contact mark are read. If the coil voltage is below what the label asks, the contact chatters, and a chattering contact burns. Low voltage also comes from a long thin run. Then the conversation is the section, not the thermal. The same discipline holds for a single-phase house pump: the protection is chosen from the motor nameplate, and silence is not solved by moving the socket breaker up one way. Silence is the hour the house is without water. That hour is an appointment slot, not a minute.
On a village line one phase's fuse may be blown while the other two remain. The motor then makes a sound as if it turns, pumps no water, and the body heats. The caller raises the thermal one turn. One turn does not complete a missing phase. What completes the picture is writing the three clamp readings side by side. If the missing phase is also in the house lighting and the neighbouring house is dark on that phase too, the report belongs to BEDAŞ. If only one contact of the motor is burnt, the report is the starter. The two reports are not joined in the same sentence. If they are joined, the distribution company's fuse is changed as if it were a contactor, and a burnt contact is reported to the company. The motor body is bonded to the board earth bar, not to a water pipe. If the bond is missing, a body leak trips the 30 mA device if there is one, not the thermal. If there is no device and the body shocks, the plug or the isolator is opened and the device work moves forward. The device is not bridged. A bridge adds a shock to a house that is already without water.
The well circuit is not left behind the house socket device. The motor's start and a wet sheath drop the fridge as well. The pump goes onto its own protection and its own 30 mA Type A unit. The unit is not put in the thermal's place. The thermal sees current. The device sees a body leak. They are not the same screw. The run is read with a 500 V megohmmeter while the motor is separated at the isolator. If the sheath hole is in the field, the whole garden is not dug. The direction where the low insulation starts is noted, and the dig is narrowed that way. Burying a drum without narrowing also breaks sound soil. This job is not a production line. A glass factory, a belt conveyor and a shift board are not written in Çatalca. What is written is the house's water and the starter that cuts that water.

The run between the well and the house is not a straight garden path. A field boundary, a wet hollow and a tractor track sit on the same route. NYM does not enter this route. If it does, the sheath hardens in one winter, cracks, and trips the device. The run is NYY. A joint is not left taped in the hollow. A buried joint is resin. A joint at the foot of a pole is in a gasketed box with the rain mouth closed. The house outdoor board is not counted as dry because it sits under an eave. Çatalca rain tires the gasket. When the gasket goes, damp sticks to the contactor coil. A stuck coil cannot stop the motor, or it never pulls. If the board cover closes with difficulty, the enclosure changes. A flame-retardant gasketed enclosure is enough. A hole is not drilled in it for anti-condensation. A drilled hole is a new path for water. If the earth bar is rusty, the bond of the motor body is renewed. Resistance is measured and written. A water pipe does not take the bar's place. An unmeasured bar is not closed with the sentence that village soil is good.
The indoor socket of a detached house is a separate complaint. If the kitchen socket heats, that box is opened before the starter is touched. If the NYA tail has carbonised it is cut, and the load is read with the clamp. A heating socket is not put right by a thermal that was raised because the well was dry. The two faults are two lines. Damp in the outdoor board does not yellow the indoor socket cover. A yellowing cover wants a loose screw. A damp coil wants a gasket and a contactor. At the appointment the question is which complaint is water and which is a socket. If it is not asked, a field drum is carried to a kitchen box. The wrong material that was carried adds a second day to a house without water. The second day is an appointment too. A minute is not tied to the tractor road.
A Çatalca call is written in the appointment book. Karacaköy and İnceğiz are not run as the two ends of the same slot. A house without water is moved forward. Moving it forward is not quoting a time that cannot be held on the village road. The slot is said before setting off. On the phone the motor isolator is asked to be opened. An open isolator stops a burnt winding from growing. Stopping it is not an arrival minute. If the whole village is dark and the meter is cold, the technician says the BEDAŞ report before setting off. An unsaid report turns into an argument about the seal at the door. We do not open the seal. If the house is lit and the motor is silent, the starter is ours. A factory, a workshop line and a shift are not inside that split. A parts list is not written for the board of a plant that is not there.
The pump starter does not invent a separate price list. The 2026 band is labour excluding materials. Fault finding is 750-1,500 TL, a contactor, a thermal or a residual-current device 1,250-3,200 TL, a socket or light 650-2,800 TL, a long supply run is discussed in the 2,400-5,500 TL band together with the measured metre, a board 6,500-16,000 TL. The NYY metre is not buried inside the band. The metre is measured at the well head and the figure is written before work starts. The survey comes off the job if the repair is accepted. The binding figure is after measurement. Workmanship is guaranteed for one year. Raising the thermal above the nameplate is not guarantee work. A raised thermal hides the cause of a burnt winding. A minute figure is not inside this band.
The house tank depends on that motor. If the lamp is on, the mains is there and the fault is in the starter. The contactor coil, the contact mark and the thermal are read. The thermal is not turned above the nameplate current. The three phases are written separately with the clamp. A missing phase makes the motor groan and pump no water. This is electrical work. The pump impeller is not this visit's claim.
The nameplate writes the current the winding can bear. If the dial is taken above it, a motor that is forced or spinning dry burns, and the house is left both without water and without a motor. The dial is not dropped so low that it trips at once on starting either. The setting is compared with the clamp reading taken while pumping. Starting current and running current are not written on the same line.
When the gasket goes, damp sticks to the contactor coil. The coil either never pulls or stays stuck. If the cover closes with difficulty, the gasketed enclosure changes. A water hole is not drilled in the enclosure. The run is NYY. NYM does not enter the field. A joint is not left taped in the hollow. If the earth bar is rusty, the motor-body bond is renewed and the resistance is written.
No. A glass factory, a production line and a shift board are not written. The job is the detached house's well starter, the long NYY and the damp of the outdoor board. A stopped motor cuts the house's water. The contactor and the thermal are read. If the village is dark and the meter is cold, the report belongs to BEDAŞ. The seal is not opened.
There is no separate pump list. The band is labour excluding materials. Finding a fault is 750-1,500 TL, a contactor or device 1,250-3,200 TL, a socket 650-2,800 TL. When a supply run is discussed, the 2,400-5,500 TL band is written together with the measured metre. A board is 6,500-16,000 TL. The NYY metre is measured at the well head and is not buried inside the band. The firm figure is after measurement. Workmanship is one year. A minute is not inside the band.
Çatalca on the European side is worked by appointment. A burning smell, arcing or a shock is moved ahead the same day; no minute is promised, because a time that cannot be held in bridge traffic helps nobody. A night or holiday difference is stated on the phone before departure.

A loose screw connection has carbonised the terminal. Take that outlet out of service at once; the point is found with a thermal camera without opening the wall.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
Branches are separated one by one at the board and the device reset; if it holds the fault is in the wiring, if not it is the device. The faulty leg is confirmed with a megohmmeter.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
If the building is dark, the record belongs to 186. If only the flat is dark, the fault is after the meter: one phase is missing or the neutral has broken. On neutral loss one phase climbs above 250 volts and another falls to 180.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
Inrush exceeds the existing circuit. The fix is not a bigger breaker but a dedicated run from the board with a motor characteristic device.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
The chandelier is fixed to the existing box and a load-rated hook. If the hook is not anchored in the slab, it is not hung. Live, neutral and earth are confirmed separately; the body is never put on phase.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
There is no protective earth and the neutral is bridged to the earth terminal in the socket. This is a lethal risk; stop using the appliance immediately.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceOn Çatalca call-outs the team follows the sequence below. No arrival minute is promised. The technician's name is given on the phone before anyone sets off.
The bands below are the labour ranges actually seen on recent call-outs and exclude materials. The binding figure is given in writing after on-site measurement, and no work starts without approval.
| Job | Typical price range | What is included |
|---|---|---|
| Fault diagnosis and measured survey | 750 TRY – 1,500 TRY | Diagnosis with a True-RMS clamp, megohmmeter and thermal camera; the survey fee is deducted if the repair is accepted. |
| Breaker / RCD replacement | 1,250 TRY – 3,200 TRY | A 30 mA Type A device; varies with the number of ways and whether Schneider or Siemens is specified. |
| Dedicated air conditioning circuit | 2,400 TRY – 5,500 TRY | 3x2.5 or 3x4 mm² solid copper with a C20-C25 breaker; varies with run length and trunking route. |
| Flat board renewal (modular DIN) | 6,500 TRY – 16,000 TRY | Varies with room count, circuit splitting and whether a surge arrester is included. |
| Chandelier, spot and socket installation | 650 TRY – 2,800 TRY | Priced per unit; heavy chandeliers include a steel anchor set into structural concrete. |
| Internet and Cat6 data cabling | 1,100 TRY – 4,200 TRY | Includes a Cat6 run per room, an RJ45 data outlet and verification with a cable tester. |
| Factory / power factor periodic maintenance | 4,500 TRY – 18,000 TRY | By panel and step count; includes a thermal sweep and a written measurement report. |
Prices are estimated labour ranges and exclude materials. A binding quote is issued in writing after the technician measures on site and before any work begins. Last updated: October 2026.
Whatever we are called out for, before leaving we measure your board at five points and leave the result in writing. It is the cheapest way to see a developing fault before it stops anything.
All breaker and terminal temperatures under load with a FLIR thermal imager; every point above seventy degrees is recorded.
The 30 mA residual current device trip time measured in milliseconds with a dedicated tester.
Voltage between neutral and earth; more than a few volts indicates a loose neutral or a bootleg ground.
Earth resistance read with a digital earth tester and assessed against the 2 Ohm target.
Breaker ratings against conductor size; anything above a C16 on a 1.5 mm² run leaves the cable unprotected.
Fully stocked mobile vans: every vehicle carries Schneider and Siemens breakers, 30 mA Type A devices, surge arresters, solid copper cable drums and junction box sets, so most jobs finish on the same visit.
Service covers the neighborhoods of Istanbul's 39 districts. Not the whole of Turkey. A survey is not a binding quote.