An electrician's call in Avcılar is usually at the joint of a column that was strengthened in a hurry after the 1999 earthquake. The shaft was opened, the phase conductor was twisted, taped and the column was closed. Years later the tape has dried, the joint has heated, and a burning smell comes from the flat cover. In student flats around the university neighbourhood and the campus, a second air conditioner, a kettle and a multi-way socket have been piled onto the same column. On the Ambarlı edge the fault is less the joint than a balcony and ground-floor socket that sea humidity has eaten. The Ambarlı shore and the generation plants are not the work of this page. The work is the joint of the residence column after the seal. The sealed meter belongs to BEDAŞ. Avcılar is on the European side, and the work is done from the appointment book. A burning smell from a column joint, arcing and a shock are that day's priority. A duration figure is not tied to the coastal road or the D100. Three empty phases are not looked for as if this were a new tower handover. How many phases actually stand in the column is written first.

  • Appointment, no minute promise
  • 10 Neighborhoods
  • 30 Services
Adnan Şemiye, ElektrikçiGO electrician, fitting an Istanbul meter cabinet
Adnan Şemiye
Adnan Şemiye, ElektrikçiGO electrician, fitting an Istanbul meter cabinet

Founding master

Adnan Şemiye18 years in the field

MYK-certified master

Adnan Şemiye reads this job in the field. The price is written before work starts.

From the field

ElektrikçiGO emergency electrician van, Istanbul 24/7Emergency van · ⁦+90 582 403 10 87⁩

A taped joint, a mixed section and student load on a strengthened column

Open flat board in Avcılar, two rows of breakers and a main switch above

Why a twisted joint left inside the jacket smells

During the 1999 strengthening the column was opened, the conductors were twisted end to end, and they were closed with cloth tape or thin insulating tape. The tape has dried, the copper has blackened, and when load comes on the joint heats and a burning smell leaves the cover. The first job is not to fit a thick wire or a larger fuse. The flat end is made dead, the cover is opened, and a joint that can be reached is read under load with a True-RMS clamp. The carbonised NYA tail is cut back and sound copper is taken into a terminal. If the joint stayed inside the column jacket, that concrete is not chased. An unreached joint is not written as sound. With the manager a new NYM route, NYY where it is needed, is chosen in the stair, and the flat is fed from that route. The old twist is not left as a spare for the new line. Two lines do not feed the flat at once. The old tail is removed. If it is not, the old joint keeps heating beside the new line at night.

In the same repair the section was mixed. 2.5 mm² NYA was jointed to a 1.5 mm² tail, and the joint disappeared inside the board. The thin side heats, the thick side stays cold, and the caller looks at the thick cable and thinks the line is sound. The section is read from the thinnest piece. Lighting in 1.5 mm² is not taken above 16 amperes. A socket run in 2.5 mm² is not left carrying a hob's continuous current and an air conditioner together. An induction hob or a portable hob in these flats is usually fed from a socket, because a 1990s kitchen has no separate hob circuit. If the hob, the washer and the air conditioner are on the same 16 ampere way, the way drops in the evening. The hob is moved to its own way and the air conditioner to its own way. If the section is short, the NYM is renewed, and the breaker is not enlarged on paper. Around the university a second air conditioner fitted in a student flat was added to the phase the repair crew could reach that day. If three phases exist at the meter and the flat was piled on one phase, the phases are separated. If the meter is single-phase, a third phase is not invented.

Night load and pulsating residual current in a student flat

Around the campus the night load is a kettle, a multi-way socket, a computer adapter and a second air conditioner. Adapters and an inverter unit produce triplen harmonics. If the column neutral is already thin and jointed, neutral current passes the phase current and one room goes bright while the next goes dim. This is not the same sentence as the LED neutral of a new residence. Here the neutral was extended in a different section during the week of the strengthening. A True-RMS clamp writes the neutral and each phase separately. An average clamp shows the joint cold. The neutral screw is tightened, the thin piece is changed, and brightness is not hidden by enlarging a phase breaker. Which flat was piled on which phase enters the note to the manager. The note is written so the next flat does not make the same joint smell the following night.

The device fitted in the hurried repair is Type AC in most flats, or it is missing. An inverter air conditioner that arrived later produces pulsating direct residual current. A Type AC unit is late on that residual, and the chassis shocks. If there is a shock, the plug comes out, the circuit is separated, and if the insulation is low the conductor is renewed first. A 30 mA Type A residual-current device is fitted onto a sound branch. A bridged device is removed. A bridge leaves a night shock open in a student flat. A circuit under one megaohm is not connected behind the new device, because the device trips again and the bridge is asked back. If the intercom or the old bell transformer is warm inside the board, the bell circuit leaves the socket. A camera adapter is tied neither to the bell pair nor to the kitchen socket. The cameras have their own breaker. An adapter fault then does not heat the column joint and does not drop the door speech.

Ambarlı humidity, the meter boundary and a price apart from the strengthening joint

Schneider Acti9 iC60N C20 miniature breaker on a DIN rail

The Ambarlı edge and an inland column are not the same smell

On the Ambarlı edge a balcony and ground-floor socket greens with sea humidity. The terminal rots, the cover goes warm, and the 30 mA device drops after rain. That drop is not the smell of a column joint inland in Gümüşpala or Firuzköy. On the shore the circuit is left dead, the green tail is cut back, and the insulation is read with a megohmmeter. A 30 mA Type A device goes back onto a sound circuit. The rotten piece is changed, and the plaster of the whole elevation is not broken for this socket. NYM stays in the dry room, and the rotten piece of the shore line is written on its own. Inland, the smell comes from the taped joint and humidity is secondary. The two faults are not made one item on the same bill. The shore socket and the column joint are separate lines. The Ambarlı generation yard, the pier and the plant cubicle are none of these lines. Those doors are not opened, and a residence board is not put in place of that yard.

If a camera on the shore is plugged into the balcony socket, the recording goes quiet in the rain and the flat's device drops as well. The camera is moved to its own breaker, and the balcony socket and the intercom are not tied to that breaker. The intercom or the old bell is on its own thin pair. In a student flat a camera adapter plugged into a multi-way socket piles night load onto the column joint. The adapter is taken out of there. The ends are passed through a cable tester. A joint left because the picture came up once goes dark in the salt air. The 1999 jacket is not drilled for the cable. The existing stair trunk or halogen-free surface trunking is used. The trunk does not carry a camera through the concrete just because the joint is inside the jacket.

After the seal the work is the joint, not a plant cubicle

If the BEDAŞ seal is intact and the meter body is cold while the smell comes from the flat cover, the joint and the flat board are measured. If the seal is already broken, or the meter side is warm, a company report is opened. We do not open the seal and we do not repair a seal. The column belongs to the building. The smell of one flat's joint makes the neighbour's joint in the same shaft suspect as well. The note left with the manager writes the floor, the phase, the change of section and whether the joint was reached. The sentence not reached is not erased from the paper. If three phases do not exist at the meter, three phases are not drawn into the flat. If a single-phase column is swollen with student load, the line is renewed or the load is separated, and a breaker is not arranged as if a phase that does not exist were there. If there is a generator or an estate board, that board needs an approval apart from the flat joint. The common screw is not undone by the owner alone.

Avcılar is entered by appointment. A burning smell from the joint, arcing and a shock are brought forward the same day. A minute is not written for the coastal road or the D100. Before setting off, the technician asks whether the smell comes from a shore socket or from a column joint. The two jobs are not put in the same bag. The 2026 band is labour, it excludes materials, and it changes with the joint: finding 750-1,500 TL, a breaker or a 30 mA Type A device 1,250-3,200 TL, a socket 650-2,800 TL, a dedicated air-conditioning or hob circuit 2,400-5,500 TL, a flat board 6,500-16,000 TL. Cutting and tightening at a joint that can be reached sit inside finding. Stair NYM, NYY and the device body sit outside. The survey is deducted if the repair is accepted. The binding amount is given after it is written whether the joint was reached or not, and before work starts. Workmanship is one year. The year is for the new line we pulled and the terminal we tightened. A twist left inside the jacket, unreached, is not part of this year. Neither is the sealed meter, nor the plant yard.

Frequently asked

Frequently asked

Is a smell from a 1999 joint in Avcılar a meter job?

If the meter body is cold and the seal is intact, the smell is at the joint and it is measured from the flat cover. We do not open the seal. An NYA tail that can be reached is cut back. If the joint stayed inside the jacket, the concrete is not chased, and a new NYM or NYY is chosen in the stair. The sentence not reached is not erased from the paper. If the meter side is warm, the report goes to BEDAŞ.

Is every Avcılar flat given three phases?

If three phases exist at the meter and the flat was piled on one phase, they are separated. If the meter is single-phase, a third phase is not invented. A second air conditioner in a student flat may have been piled on the phase the crew could reach that day. The section is read from the thinnest piece, and 1.5 mm² is not taken above 16 amperes. A True-RMS clamp is written under load.

Why does the breaker trip at night around the university?

A kettle, a multi-way socket, an adapter and a second air conditioner pile onto the same way and a thin neutral. Harmonic current gathers in the jointed neutral, and one room goes bright while the other goes dim. This is not the LED neutral of a new residence. If the section is mixed, the thin piece changes. If the device is bridged, it is removed, and 30 mA Type A is fitted onto a sound circuit. A shock is brought forward the same day.

Are Ambarlı humidity and an inland column joint the same repair?

They are not. On the shore there is a green terminal and a device that drops after rain. Inland a taped joint smells. The two are separate lines. The camera leaves the balcony socket and is moved to its own breaker. The plant yard, the pier and the generation cubicle are not opened. A residence board is not written in place of that yard.

When is an Avcılar electrician amount for 2026 written?

After it is written whether the joint was reached or not. The labour band is finding 750-1,500 TL, a device or breaker 1,250-3,200 TL, a socket 650-2,800 TL, an air-conditioning or hob circuit 2,400-5,500 TL, a board 6,500-16,000 TL. Stair cable and the device body are excluded. There is no minute. Workmanship is one year, and it does not cover a twist left inside the jacket or the sealed meter.

How is a night or Sunday call planned in Avcılar?

Avcılar on the European side is worked by appointment. A burning smell, arcing or a shock is moved ahead the same day; no minute is promised, because a time that cannot be held in bridge traffic helps nobody. A night or holiday difference is stated on the phone before departure.

Services

PLC programmingindustrial electrical serviceShort circuithome–plant electrical serviceSocket and switchhome electrical serviceResidual-current devicehome electrical serviceEarthinghome–plant electrical serviceCable and circuit runhome electrical serviceRewiringhome electrical serviceTelevision mountingelectrical fitting serviceAC Electrical Wiringresidential–commercial AC serviceIntercom & Doorbell Systemsresidential intercom serviceFuse & Panel Faultsconsumer unit & panel serviceChandelier Mounting & Lightingresidential lighting serviceInternet & Data Cablingresidential & office network serviceElectrical Fault Repair24/7 emergency fault serviceDistribution Board Setupresidential–commercial panel serviceEarthing & Lightning Protectionbuilding earthing & surge serviceSecurity Camera Systemssurveillance & CCTV serviceEV Charger InstallationEV charging infrastructure serviceSmart Home Automationsmart home & KNX/Zigbee serviceHalf The House Has No Powerpartial outage & phase loss repairBurning Smell and Crackling Socketsemergency thermal inspection & arc repairVoltage Fluctuation, Regulators and UPSvoltage protection & uninterruptible powerGenerator and ATS Paneltransfer panelMeter, Main Switch and Risercustomer side after the meterLift and Hydrophore Panelpanel supplySolar Inverter Board Connectioncustomer-side AC outputPanel faultLighting installationBreaker replacementSecurity camera

What Can You See At Home? Fast Diagnosis By Symptom

There is a burning smell from a socket

Single socket being checked for burn marks

A loose screw connection has carbonised the terminal. Take that outlet out of service at once; the point is found with a thermal camera without opening the wall.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

The breaker keeps tripping

Main switch and breaker row

Branches are separated one by one at the board and the device reset; if it holds the fault is in the wiring, if not it is the device. The faulty leg is confirmed with a megohmmeter.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

The flat has lost power

Meter measuring voltage

If the building is dark, the record belongs to 186. If only the flat is dark, the fault is after the meter: one phase is missing or the neutral has broken. On neutral loss one phase climbs above 250 volts and another falls to 180.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

The breaker trips when the AC or oven starts

Breaker dedicated to an appliance circuit

Inrush exceeds the existing circuit. The fix is not a bigger breaker but a dedicated run from the board with a motor characteristic device.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

A chandelier needs fitting

Chandelier on the ceiling

The chandelier is fixed to the existing box and a load-rated hook. If the hook is not anchored in the slab, it is not hung. Live, neutral and earth are confirmed separately; the body is never put on phase.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

I get a shock from the sink or washing machine

Washing machine socket connection

There is no protective earth and the neutral is bridged to the earth terminal in the socket. This is a lethal risk; stop using the appliance immediately.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

How Our Field Team Works A Call

On Avcılar call-outs the team follows the sequence below. No arrival minute is promised. The technician's name is given on the phone before anyone sets off.

  1. 01
    Symptom
    The residual current device trips again the instant it is reset
    Measurement
    Branches are separated one by one at the board and each leg measured with a 500 V megohmmeter. Insulation resistance below 1 Megaohm shows that run's insulation is no longer doing its job.
    Intervention
    The faulty leg is isolated and the refrigerator, boiler and lighting restored within the first ten minutes. If damp is the cause the junction box is dried and encapsulated in dielectric gel; if the insulation is charred the run is renewed back to the board.
  2. 02
    Symptom
    A burning smell from a socket with a deformed face plate
    Measurement
    A FLIR thermal sweep is taken under load; where a loose screw connection has carbonised the terminal, that point reads between 160 and 200 degrees and is found without opening the wall.
    Intervention
    Blackened conductor ends are cut back to clean copper, the back-box replaced and the joint closed with a Wago 221 lever terminal. Every screw connection is tightened with a calibrated screwdriver to between 2.5 and 3.5 Nm.
  3. 03
    Symptom
    Half the flat has no power while the other half works
    Measurement
    Voltage is read phase by phase downstream of the meter. On neutral loss one phase measures above 250 volts and another around 180; that pattern burns appliance boards the same night.
    Intervention
    The main neutral terminals are opened, oxidised surfaces cleaned with dielectric solvent and torqued to specification. An over/undervoltage protection relay is added so appliances survive the next neutral loss.

2026 Electrician Prices and Recently Completed Jobs

The bands below are the labour ranges actually seen on recent call-outs and exclude materials. The binding figure is given in writing after on-site measurement, and no work starts without approval.

2026 Electrician Prices and Recently Completed Jobs
JobTypical price rangeWhat is included
Fault diagnosis and measured survey750 TRY – 1,500 TRYDiagnosis with a True-RMS clamp, megohmmeter and thermal camera; the survey fee is deducted if the repair is accepted.
Breaker / RCD replacement1,250 TRY – 3,200 TRYA 30 mA Type A device; varies with the number of ways and whether Schneider or Siemens is specified.
Dedicated air conditioning circuit2,400 TRY – 5,500 TRY3x2.5 or 3x4 mm² solid copper with a C20-C25 breaker; varies with run length and trunking route.
Flat board renewal (modular DIN)6,500 TRY – 16,000 TRYVaries with room count, circuit splitting and whether a surge arrester is included.
Chandelier, spot and socket installation650 TRY – 2,800 TRYPriced per unit; heavy chandeliers include a steel anchor set into structural concrete.
Internet and Cat6 data cabling1,100 TRY – 4,200 TRYIncludes a Cat6 run per room, an RJ45 data outlet and verification with a cable tester.
Factory / power factor periodic maintenance4,500 TRY – 18,000 TRYBy panel and step count; includes a thermal sweep and a written measurement report.

Prices are estimated labour ranges and exclude materials. A binding quote is issued in writing after the technician measures on site and before any work begins. Last updated: October 2026.

A Free Five-Point Board Safety Check On Every Call-Out

Whatever we are called out for, before leaving we measure your board at five points and leave the result in writing. It is the cheapest way to see a developing fault before it stops anything.

01

All breaker and terminal temperatures under load with a FLIR thermal imager; every point above seventy degrees is recorded.

02

The 30 mA residual current device trip time measured in milliseconds with a dedicated tester.

03

Voltage between neutral and earth; more than a few volts indicates a loose neutral or a bootleg ground.

04

Earth resistance read with a digital earth tester and assessed against the 2 Ohm target.

05

Breaker ratings against conductor size; anything above a C16 on a 1.5 mm² run leaves the cable unprotected.

Fully stocked mobile vans: every vehicle carries Schneider and Siemens breakers, 30 mA Type A devices, surge arresters, solid copper cable drums and junction box sets, so most jobs finish on the same visit.

Services We Provide In This Area

Neighborhoods

Service covers the neighborhoods of Istanbul's 39 districts. Not the whole of Turkey. A survey is not a binding quote.