November 2026 updated price and service guide
Certified electrician network
Electrician Istanbul: Home Wiring, Sockets, Breakers and Boards
5.0 / 5.0 on Google · 2 verified reviews- On-call from Pendik · European side by appointment · no minute promise
- State-Certified Mastery Qualification · Invoiced With A 1 Year Guarantee
- No Surprise Charges · Clear Price Approval Before Work
- TSE & ISO referenced materials · Scan slots on the certificates page
A breaker tripped, a socket burnt, or half the flat has no power. We route your call to the nearest suitable technician; they measure first, then put your price in writing. No work starts on anything you have not approved.

Call a certified electrician
Asian side 24/7 emergency. European side by appointment. Arrival time is confirmed on the call.
What Can You See At Home? Fast Diagnosis By Symptom
There is a burning smell from a socket

A loose screw connection has carbonised the terminal. Take that outlet out of service at once; the point is found with a thermal camera without opening the wall.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceThe breaker keeps tripping

Branches are separated one by one at the board and the device reset; if it holds the fault is in the wiring, if not it is the device. The faulty leg is confirmed with a megohmmeter.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceThe flat has lost power

If the building is dark, the record belongs to 186. If only the flat is dark, the fault is after the meter: one phase is missing or the neutral has broken. On neutral loss one phase climbs above 250 volts and another falls to 180.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceThe breaker trips when the AC or oven starts

Inrush exceeds the existing circuit. The fix is not a bigger breaker but a dedicated run from the board with a motor characteristic device.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceA chandelier needs fitting

The chandelier is fixed to the existing box and a load-rated hook. If the hook is not anchored in the slab, it is not hung. Live, neutral and earth are confirmed separately; the body is never put on phase.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceI get a shock from the sink or washing machine

There is no protective earth and the neutral is bridged to the earth terminal in the socket. This is a lethal risk; stop using the appliance immediately.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceFault searches
The sentences typed before and after electrician
Socket, breaker, air-conditioner, night and district searches go to their own page. The list stays closed; the sentences stay on the page.
Sockets and switches
- socket burning smell emergency electrician
That socket is taken out of use and the plug is pulled. Arcing from a loose terminal is read with a thermal camera, and blackened copper is cut back to clean metal. The binding figure is written on site.
650–2,800 TRY
- sparking socket electrician
A spark means the screw torque has fallen. With the circuit off, the tail is tightened to 2.5–3.5 Nm. A melted body is replaced. The amp rating is not increased.
650–2,800 TRY
- socket pulled out of the wall repair
A box that moves in the wall gets a new plug and an earthed mechanism. If the NYM tail is short, the joint is made in the box, not buried in plaster.
650–2,800 TRY
- melted triple socket and a tripped breaker
A triple adaptor piled onto one circuit is the load. The melted body is replaced and the circuit is read with a clamp. The breaker stays at the same rating.
650–2,800 TRY
Breakers and the board
- breaker tripped and will not hold electrician
The lever is not forced. Plugs come out and the cover stays shut. A lever that will not hold is separated from a cable fault with a True-RMS clamp and a megohmmeter. The same amp rating goes back.
1,250–3,200 TRY
- residual current device keeps tripping electrician
A 30 mA device does not replace the thermal breaker. Leakage is split circuit by circuit with a clamp. The device is not bridged before a damp circuit or a neutral-to-earth join is found.
1,250–3,200 TRY
- main switch heating and smelling
A hot lever is a loose incoming terminal. The cover is not opened live. The heated tail is cleaned and torqued. The board is not closed until the smell has a source.
1,250–3,200 TRY
- ceramic fuse board replacement
A porcelain fuse board is moved onto a modular DIN enclosure. Schneider or Siemens breakers and a 30 mA Type A device are specified. Changing one fuse is not a full board renewal.
6,500–16,000 TRY
Air conditioner, oven, boiler, washer
- breaker trips when the air conditioner starts electrician
The air conditioner gets its own circuit: 3x2.5 or 3x4 mm² copper, C20 or C25. Left on a socket circuit, the inrush drops the breaker.
2,400–5,500 TRY
- built-in oven keeps tripping the breaker
A built-in oven is a continuous load. It is not left on a shared socket. Cable size and the C curve are read on site, and the price is written before work.
2,400–5,500 TRY
- boiler has no power and trips the breaker
The boiler board and the circuit are separated. If the residual-current device trips, the appliance plug comes out and the circuit is read again. A failed control board is not a breaker job.
1,250–3,200 TRY
- water heater cable heating electrician
A hot cable is a loose tail or a thin section. The plug comes out and the tail is read thermally. If the section is too small a dedicated circuit is written. A melted socket body is replaced.
650–2,800 TRY
- dishwasher trips the breaker electrician
If the dishwasher drops on the heating step, the element and the circuit are separated. The plug comes out. A 30 mA device is not bridged. If the leakage is in the appliance, the part is written to the machine service.
1,250–3,200 TRY
- washing machine trips the breaker electrician
If the washer holds at the start and drops when it heats, the element is in circuit. The breaker and the residual-current device are not mixed up. The amp rating is not increased.
1,250–3,200 TRY
- washing machine body gives a shock
A shock from the body means the earth path is open, or neutral and earth meet after the device. The machine plug comes out. Nothing is bridged before the resistance is measured.
750–1,500 TRY
Lighting and a partial outage
- half the flat has power some rooms are dark
Half the flat usually means one phase is down. The neighbouring flat is checked, then the board is read with a clamp. A breaker is not upsized before the phase is back.
750–1,500 TRY
- my flat is dark the building still has power electrician
If the building has power and the flat is dark, the fault is after the meter. If the whole building is dark, 186 is the AYEDAŞ or BEDAŞ call. They are not the same job.
750–1,500 TRY
- home electrician who hangs a chandelier
A heavy chandelier is hung from structural concrete with a steel anchor. A plasterboard hook is not left on its own. The joint is a terminal, not a twist and tape.
650–2,800 TRY
- LED spots and bulbs keep flickering
Flicker is a loose neutral or a driver heating in a sealed void. The driver is moved where it can breathe and the neutral tail is torqued. Changing the lamp alone does not finish it.
650–2,800 TRY
Night, Sunday and 24/7
- on-call electrician open at night
A night call uses the same measurement. If the rate differs, that is said on the phone before anyone sets off. No minute promise is made.
- Sunday electrician
Sunday and public holidays stay on the line. Work does not start before the price is written. A holiday difference, if there is one, is said on the call.
- 24/7 emergency electrician
The emergency page is for a burning smell, a breaker that will not hold, and a dark flat. Time and price are not locked before the measurement.
Electrician plus a district
- Pendik electrician
The Pendik page carries that district's own fault note. The Istanbul page does not stand in for it.
- Kartal electrician
A Kartal call goes to the Kartal page. The neighbourhood note is there, and it is not padded with a copied sentence.
- Maltepe electrician
Maltepe has its own page. The same text is not pasted onto Pendik.
- Kadıköy electrician
The Kadıköy page describes the faults of the shore flats. The general Istanbul text is not copied there.
- Tuzla electrician
The Tuzla page is that district's own note. Gebze is not a service area.
Electrician plus a price
- electrician prices 2026
The 2026 list opens with a survey at 750–1,500 TRY. The band is an estimate. The binding figure is written on site, then the work starts.
750–1,500 TRY
- how much does an electrician charge
There is no figure locked on the phone. The survey band is written, and the amount is settled after the measurement.
750–1,500 TRY
What happens after you call: five steps
1. The call and a first read
On the phone we ask which room went dark, whether there is a smell, and which appliance was running when it started. Those three answers decide what the technician brings in the van and save a second trip.
2. An arrival window for your area
Asian-side emergencies are taken 24/7. The European side is by appointment. The islands follow the ferry. Arrival time is confirmed on the call.
3. Measurement on site
The technician measures first: current with a True-RMS clamp, insulation resistance with a Megger and, where needed, hot spots with a thermal camera. The board cover is not opened before measurement and approval.
4. A written price and your approval
When the measurement is done the binding figure is put in writing. No work starts on any item you have not approved, and if extra work appears approval is sought again.
5. Handover, invoice and guarantee
The brand and model of materials used, the measured values and any circuits recommended for renewal go onto a signed service report. The job is invoiced and the workmanship carries a 1 year guarantee.
What if you do not accept the quote? You pay only the survey fee stated up front on the call. The measured values stay with you in writing; nothing else is added and no work begins.
2026 Electrician Prices and Recently Completed Jobs
The bands below are the labour ranges actually seen on recent call-outs and exclude materials. The binding figure is given in writing after on-site measurement, and no work starts without approval.
| Job | Typical price range | What is included |
|---|---|---|
| Fault diagnosis and measured survey | 750 TRY – 1,500 TRY | Diagnosis with a True-RMS clamp, megohmmeter and thermal camera; the survey fee is deducted if the repair is accepted. |
| Breaker / RCD replacement | 1,250 TRY – 3,200 TRY | A 30 mA Type A device; varies with the number of ways and whether Schneider or Siemens is specified. |
| Dedicated air conditioning circuit | 2,400 TRY – 5,500 TRY | 3x2.5 or 3x4 mm² solid copper with a C20-C25 breaker; varies with run length and trunking route. |
| Flat board renewal (modular DIN) | 6,500 TRY – 16,000 TRY | Varies with room count, circuit splitting and whether a surge arrester is included. |
| Chandelier, spot and socket installation | 650 TRY – 2,800 TRY | Priced per unit; heavy chandeliers include a steel anchor set into structural concrete. |
| Internet and Cat6 data cabling | 1,100 TRY – 4,200 TRY | Includes a Cat6 run per room, an RJ45 data outlet and verification with a cable tester. |
| Factory / power factor periodic maintenance | 4,500 TRY – 18,000 TRY | By panel and step count; includes a thermal sweep and a written measurement report. |
Prices are estimated labour ranges and exclude materials. A binding quote is issued in writing after the technician measures on site and before any work begins. Last updated: October 2026.
Our primary service areas
Our primary 24/7 emergency area is the Anatolian side (Pendik, Kartal, Maltepe, Kadıköy, Ataşehir, Ümraniye, Tuzla, Sultanbeyli, Çekmeköy, Sancaktepe, Beykoz, Üsküdar, Şile). Adalar is taken by appointment against the ferry timetable; a midnight crossing is not promised. The European side is by appointment. Arrival time is confirmed on the call. No promised minute count.
- Pendik electrician36 neighbourhoods
- Tuzla electrician17 neighbourhoods
- Kartal electrician20 neighbourhoods
- Maltepe electrician18 neighbourhoods
- Kadıköy electrician21 neighbourhoods
- Üsküdar electrician33 neighbourhoods
- Ümraniye electrician35 neighbourhoods
- Ataşehir electrician17 neighbourhoods
- Sancaktepe electrician19 neighbourhoods
- Çekmeköy electrician21 neighbourhoods
- Beykoz electrician45 neighbourhoods
- Sultanbeyli electrician15 neighbourhoods
- Şile electrician62 neighbourhoods
- Bağcılar electrician22 neighbourhoods
- Fatih electrician57 neighbourhoods
- Beyoğlu electrician45 neighbourhoods
- Beşiktaş electrician23 neighbourhoods
- Şişli electrician25 neighbourhoods
- Bakırköy electrician15 neighbourhoods
- Zeytinburnu electrician13 neighbourhoods
- Bayrampaşa electrician11 neighbourhoods
- Eyüpsultan electrician29 neighbourhoods
- Bahçelievler electrician11 neighbourhoods
- Başakşehir electrician10 neighbourhoods
- Beylikdüzü electrician10 neighbourhoods
- Esenyurt electrician43 neighbourhoods
- Küçükçekmece electrician21 neighbourhoods
- Avcılar electrician10 neighbourhoods
- Gaziosmanpaşa electrician16 neighbourhoods
- Esenler electrician17 neighbourhoods
- Sultangazi electrician15 neighbourhoods
- Güngören electrician11 neighbourhoods
- Kağıthane electrician19 neighbourhoods
- Adalar electrician5 neighbourhoods
- Sarıyer electrician38 neighbourhoods
- Büyükçekmece electrician24 neighbourhoods
- Çatalca electrician39 neighbourhoods
- Silivri electrician35 neighbourhoods
- Arnavutköy electrician38 neighbourhoods
The workmanship guarantee and what it covers
1 Year Official Workmanship Guarantee
- The workmanship our technician performed: board installation, circuit runs, terminal and socket connections, earthing installation.
- Switchgear we supplied, for the manufacturer's warranty period and within its terms.
- A recurrence of the same fault at the same point: no survey fee is charged on the return visit.
Not covered
- Later interventions or added circuits by the customer or a third party.
- Failure of equipment or materials we did not supply; in that case only the workmanship is covered.
- External events such as lightning, flooding, fire and grid overvoltage; arresters and protection relays are recommended against these.
- Faults arising from circuits the measurement report advised renewing that the customer chose not to renew.
Frequently asked questions
Which districts do you reach 24/7 for emergencies?
Our primary 24/7 emergency area is the Anatolian side (Pendik, Kartal, Maltepe, Kadıköy, Ataşehir, Ümraniye, Tuzla, Sultanbeyli, Çekmeköy, Sancaktepe, Beykoz, Üsküdar, Şile). Adalar is taken by appointment against the ferry timetable; a midnight crossing is not promised. The European side is by appointment. Arrival time is confirmed on the call. No promised minute count. A MYK-certified master electrician. The job runs on the founder's expert line. There is no twenty-van fleet.
What does a certified electrician actually prove?
A certificate shows that a person was assessed at a defined qualification level, or that they are authorised for internal installations. It does not by itself prove that protection in a given panel was selected correctly, that earth continuity was measured, or that the residual-current type matches the load. A competent electrician carries the certificate together with the measurement record.
Which standard governs low-voltage installations in Turkey?
The frame is the internal electrical installations regulation. The working language is the TS HD 60364 series. Panel assemblies are read with TS EN 61439, machinery with TS EN 60204-1, and operation with TS EN 50110-1. A brand family does not replace those texts.
Are a residential electrician and an industrial electrician the same authority?
No. The residential hand builds final circuits, breaker curves, 30 mA protection and wet rooms. The industrial hand reads the motor nameplate, the thermal setting, the emergency stop, the PLC backup and the drive type. Neither closes the other's panel out of habit. The job is separated before the cover is opened.
Is the installation finished once an earth rod is driven?
No. The foundation earth electrode, protective-conductor continuity, equipotential bonding and loop impedance are separate jobs. Rod resistance alone does not say the breaker will open on a fault. After PE and neutral are separated they are not joined again.
Why is a residual-current device chosen at 30 mA?
30 mA is the residual threshold used to protect a person on a final circuit. A breaker does not see that threshold. 300 mA may sit upstream for fire protection in some installations and does not replace 30 mA. Raising the threshold to stop a trip removes the protection.
What an electrician is, and what this page is for
An electrician is a certified person who locates and repairs a fault in an installation by measurement: the board, the circuits, the earthing and the protection arrangement are their responsibility. This page exists so you can call one; the trade's standards, which certificate to ask for and how to choose an electrician are set out in a separate guide.
Prices are estimated labour ranges and exclude materials. A binding quote is issued in writing after the technician measures on site and before any work begins. Last updated: October 2026.
What an electrician does and how to choose one →Google Review
Happy With The Work? Leave Us 5★ On Google
Your review is how neighbours searching for an emergency electrician in your area find us. One tap opens the Google review page; there is no account to create and no form to fill in.
Current rating: 5.0 / 5.0 · 2 verified reviews
Leave 5★ On Google