
Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
November 2026 updated price and service guide
Districts
An electrician in Silivri goes by appointment to a summer house on the far shore. Selimpaşa, Gümüşyaka and Kavaklı fill at the weekend and empty on Monday. A house left closed through winter trips the 30 mA residual-current device on the first opening. Damp works into the socket box, the outdoor luminaire and the water-heater body through the closed season. At opening, the whole house loads the device at once. The device is not bridged. The circuits are separated while dead, and the tripping way is read with a 500 V megohmmeter. Here the house has stayed closed for months and has taken salt shore damp instead of air. Distance is not a night arrival. The call is written in the appointment book. A full Saturday is not turned into a night crossing. The sealed meter belongs to BEDAŞ. The seal is not opened. The board after the meter and the wet box are our measurement.


Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
From the field
Emergency van · +90 582 403 10 87
Air does not move in a closed house. Shore damp leaves a salty film inside the socket cover. The film sits as if dry through winter and becomes a conductor on the first wet opening. If the glass of an outdoor luminaire has cracked, the inside is full of water. If a water heater stayed closed and plugged in for months, the element leaks to the body. If a fridge was left plugged into a damp socket, the compressor's first start also drops the device. If four sources sit behind the same 30 mA unit, they all arrive together at opening. The caller thinks the device is bad. What is bad is usually a way, not the device. The first job is not a bridge. The main switch goes down, every way goes down, and the device is raised. If the device does not hold with nothing on it, the unit itself is tried. If it holds empty, the ways are raised one by one. The fault is on the way that, once lowered, lets the device hold. That way's box is opened while it is dead. Water, a green tail or swollen NYA is seen. The tail is cut. The outdoor luminaire is emptied, and if its gasket is finished the body changes. The water-heater plug comes out and the body leak is read separately. The fridge is not started before it is taken off the wet socket onto another circuit.
At opening it is not necessary to dry every box at once. The tripping way is found, that way is finished, and the others stay. A sound circuit that stayed is not renewed because 'the house is damp'. If it is renewed, the invoice swells and the wet luminaire remains. If the megohmmeter reading is under one megaohm, that circuit is not connected behind a new 30 mA Type A device. If it is above and the tail is clean, the device goes back. Type AC is not preferred for a water heater and a fridge that leave a pulsed current. Type A is written. The outdoor luminaire and the indoor socket are not left on the same device. The outdoor run is separated. If it is not, the next rain also drops the kitchen socket that was just cleaned. NYM is not left on an outdoor wall. If an outdoor run is needed, NYY and a gasketed body are used. Old indoor NYA is not extended outdoors before it is dry. An extension carries the closed season's film one metre further.
A house that left for winter with the device bridged leaves a body leak to the breaker in spring. The breaker does not see the leak that 30 mA sees. The water-heater body and the wet outdoor luminaire shock. The shock becomes the first complaint of opening day. The bridge wire is removed, not thrown away, and a note is written of its photograph and which tail it came off. A 30 mA Type A goes in its place, and only a way that passes the megohmmeter is connected. A way that does not pass is not put back behind the bridge. If it is put back, the new device trips as well and the caller asks for a bridge again. The bridge that is asked for is not written. What is written is which box held water. If the board cover stayed open through winter, the bar is rusty. The conductor is cut before a rusty screw is tightened. Tightened rust does not bring the contact back. A Schneider or Siemens enclosure is discussed in place of a summer-house case whose cover will not close only after the bar is cleaned. Screwing a new enclosure onto a dirty bar locks the damp inside.
The opening measurement does not end with one socket. The water heater, the outdoor luminaire, the fridge socket and the board bar are four lines. One being clean does not count the next as passed. In a summer house whose lower floor is at ground level, the skirting socket is below the water line. That socket is not left open because the upstairs socket is sound. If it is left, damp rising from the ground at night drops only that way, and the caller blames the whole device again. An earth rod on a sandy shore can read high. The reading is written. 'The summer house is earthed' is not said before that. A water pipe is not made into an earth. A high resistance is not a reason to bridge the device. The device is the remaining protection for a body leak when the resistance is high. The rod work is a separate line and can be a second appointment. The second appointment does not add a minute to opening day.

At the weekend the Silivri shore fills with the same complaint: we opened the door and the device tripped. Each house wants its own opening measurement. The measurement is not inherited from the previous house's bridge. A water-heater leak in Selimpaşa, water in a luminaire in Gümüşyaka and a skirting socket in Kavaklı are not the same parts list. The list is split on the phone. If the van leaves before that split, the device finished at the first house has taken the gasket the second house needs. A full Saturday is an appointment book for that reason, not a minute queue. The slot is said before setting off. The slot that is said does not shorten the road of the far shore. A night arrival is not written. A burning smell or a shock is moved forward in the book. Moving it forward is not tying a time to the shore road in the dark. On the phone, if there is a bridge, the instruction is not to touch it, to pull the water-heater plug, and not to reach into the outdoor luminaire with a bare hand. Those three sentences take the place of a night arrival that is not there.
A house that empties on Monday is not left inside the bridge made on Saturday. If it is left, a shock on Tuesday arrives after Monday's journey. The appointment writes the work that will close before the return: was the bridge removed, which way was separated, is the outdoor run on a separate device. An unwritten return opens the same door again the next weekend. The BEDAŞ seal sits outside this list. If the meter is cold and the neighbouring summer house is dark too, the report belongs to the distribution company. If one house's device is tripping and the neighbour is lit, the side after the meter is ours. The two situations get mixed in the Saturday crowd. So they do not mix, the first line of the paper is the neighbour's light. If the light is there, the argument about the seal does not grow. If it does not grow, the slot does not spill into a night arrival that is not there.
The opening measurement of a house closed through winter sits in the finding band. Putting a 30 mA Type A in place of a bridged device sits in the device band. A gasketed socket and an outdoor luminaire sit in the socket and lighting band. If an air-conditioning circuit is to be pulled separately, it has its own band. If the board enclosure is to change, it sits in the board band. The 2026 figures are labour excluding materials: finding 750-1,500 TL, a breaker or residual-current device 1,250-3,200 TL, a socket or light 650-2,800 TL, an air-conditioning circuit 2,400-5,500 TL, a board 6,500-16,000 TL. Changing all four sources at once is not adding four bands without measuring. The tripping way is found and the others stay. The NYY metre is not buried inside the band. The metre is measured on the outdoor wall. The survey comes off the job if the repair is accepted. The binding figure is written after measurement and before work starts. Workmanship is guaranteed for one year. That year is not permission to spend the next winter closed and bridged. A minute figure is not inside the band.
The far shore does not put a night surcharge on top of the band. What is put is the slot said before setting off. The slot and the band are not mixed. If they are mixed, a finding job is written onto the board band because the road is long. It is not written that way. Finding ends when the tripping way is found. The board enclosure does not change before the way is found. An enclosure change is discussed if there is bar rust and a cover that will not close. The discussion is after measurement. Weekend haste does not break that order. If it breaks it, a device fitted on Saturday still stands beside a water heater that is bridged on Monday. The guarantee does not cover that water heater's body leak. What covers it is pulling the plug and reading the element separately. If the reading is not on the paper, the job is not counted as finished.
Through the closed season damp works into the socket box, a cracked outdoor luminaire and a water heater left plugged in. At opening they all load the same 30 mA unit. The device is not bridged. The ways go down and are raised one by one, and the tripping way is read with a 500 V megohmmeter. Under one megaohm it is not connected behind the new device. A sound circuit is not renewed because the house is damp.
Saturday fills with the same complaint, and each house's opening measurement is separate. Selimpaşa, Gümüşyaka and Kavaklı are not the same parts list. The list is split on the phone. The slot is said before setting off. A night arrival and a minute queue are not written. A burning smell is moved forward in the book. Moving it forward is not quoting a time.
No. A device bridged through winter leaves a water-heater body shock to the breaker in spring. The bridge wire is removed and written down. A 30 mA Type A goes in its place. A way that fails the megohmmeter is not connected. The outdoor luminaire is separated from the indoor socket. A high earth resistance is not a reason to bridge. The device is the protection that remains at that resistance.
The sealed meter is a BEDAŞ report. We do not open the seal. If the meter is cold and the neighbouring summer house is dark too, the company is called. If one house's device is tripping and the neighbour is lit, the board and the box after the meter are our measurement. The first line of the paper is the neighbour's light. If the light is there, the argument about the seal does not grow.
The far shore does not put on a night surcharge. The band is labour excluding materials. Finding a fault is 750-1,500 TL, a device or breaker 1,250-3,200 TL, a socket or luminaire 650-2,800 TL, an air-conditioning circuit 2,400-5,500 TL, a board 6,500-16,000 TL. At opening, four sources are not changed at once. The tripping way is found. The firm figure is written after measurement. Workmanship is one year. A minute is not inside the band.
Silivri on the European side is worked by appointment. A burning smell, arcing or a shock is moved ahead the same day; no minute is promised, because a time that cannot be held in bridge traffic helps nobody. A night or holiday difference is stated on the phone before departure.

A loose screw connection has carbonised the terminal. Take that outlet out of service at once; the point is found with a thermal camera without opening the wall.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
Branches are separated one by one at the board and the device reset; if it holds the fault is in the wiring, if not it is the device. The faulty leg is confirmed with a megohmmeter.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
If the building is dark, the record belongs to 186. If only the flat is dark, the fault is after the meter: one phase is missing or the neutral has broken. On neutral loss one phase climbs above 250 volts and another falls to 180.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
Inrush exceeds the existing circuit. The fix is not a bigger breaker but a dedicated run from the board with a motor characteristic device.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
The chandelier is fixed to the existing box and a load-rated hook. If the hook is not anchored in the slab, it is not hung. Live, neutral and earth are confirmed separately; the body is never put on phase.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
There is no protective earth and the neutral is bridged to the earth terminal in the socket. This is a lethal risk; stop using the appliance immediately.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceOn Silivri call-outs the team follows the sequence below. No arrival minute is promised. The technician's name is given on the phone before anyone sets off.
The bands below are the labour ranges actually seen on recent call-outs and exclude materials. The binding figure is given in writing after on-site measurement, and no work starts without approval.
| Job | Typical price range | What is included |
|---|---|---|
| Fault diagnosis and measured survey | 750 TRY – 1,500 TRY | Diagnosis with a True-RMS clamp, megohmmeter and thermal camera; the survey fee is deducted if the repair is accepted. |
| Breaker / RCD replacement | 1,250 TRY – 3,200 TRY | A 30 mA Type A device; varies with the number of ways and whether Schneider or Siemens is specified. |
| Dedicated air conditioning circuit | 2,400 TRY – 5,500 TRY | 3x2.5 or 3x4 mm² solid copper with a C20-C25 breaker; varies with run length and trunking route. |
| Flat board renewal (modular DIN) | 6,500 TRY – 16,000 TRY | Varies with room count, circuit splitting and whether a surge arrester is included. |
| Chandelier, spot and socket installation | 650 TRY – 2,800 TRY | Priced per unit; heavy chandeliers include a steel anchor set into structural concrete. |
| Internet and Cat6 data cabling | 1,100 TRY – 4,200 TRY | Includes a Cat6 run per room, an RJ45 data outlet and verification with a cable tester. |
| Factory / power factor periodic maintenance | 4,500 TRY – 18,000 TRY | By panel and step count; includes a thermal sweep and a written measurement report. |
Prices are estimated labour ranges and exclude materials. A binding quote is issued in writing after the technician measures on site and before any work begins. Last updated: October 2026.
Whatever we are called out for, before leaving we measure your board at five points and leave the result in writing. It is the cheapest way to see a developing fault before it stops anything.
All breaker and terminal temperatures under load with a FLIR thermal imager; every point above seventy degrees is recorded.
The 30 mA residual current device trip time measured in milliseconds with a dedicated tester.
Voltage between neutral and earth; more than a few volts indicates a loose neutral or a bootleg ground.
Earth resistance read with a digital earth tester and assessed against the 2 Ohm target.
Breaker ratings against conductor size; anything above a C16 on a 1.5 mm² run leaves the cable unprotected.
Fully stocked mobile vans: every vehicle carries Schneider and Siemens breakers, 30 mA Type A devices, surge arresters, solid copper cable drums and junction box sets, so most jobs finish on the same visit.
Service covers the neighborhoods of Istanbul's 39 districts. Not the whole of Turkey. A survey is not a binding quote.
35 / 35 · Residential neighborhoods sit first.
Google Review
Your review is how neighbours searching for an emergency electrician in your area find us. One tap opens the Google review page; there is no account to create and no form to fill in.
Current rating: 5.0 / 5.0 · 2 verified reviews
Leave 5★ On Google