Adnan Şemiye reads this job in the field. The price is written before work starts.
November 2026 updated price and service guide
Districts
In Beylikdüzü the call usually comes from the estate management, not from a single old flat. In the residences of Adnan Kahveci, Barış, Yakuplu and Gürpınar the outdoor air-conditioning units start within the same half hour on a summer afternoon. On the marina-side podiums of Sahil and Yakuplu the fault is not the air conditioner. It is a ground-floor socket that salt humidity has eaten. The management board carries the booster pump, the barrier and the lobby lighting. The flat board carries the hob and the split unit. The two are written on the same paper and are not treated as the same screw. If the induction hob is piled on one phase with the south-elevation air conditioner, that phase sags, and if the pump on the management board is on that phase as well, the lobby and the flat go quiet together. The sealed meter belongs to BEDAŞ. The transformer and the meter ahead of the seal are not a door we open. Beylikdüzü is on the European side, and the job is in the appointment book. The smell of a burning socket, arcing and a shock are brought forward the same day. A duration figure is not left for an evening on the E-5.


Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
From the field
Emergency van · +90 582 403 10 87
On a Beylikdüzü residence the south elevation fills up after noon. The starting current of an outdoor unit is several times the running current. If the contractor brought two air-conditioning risers and the kitchen induction hob down on one phase, that phase's voltage falls, the compressor locks, and the breaker in the flat trips. The caller says the estate electricity is weak. The diagnosis is taken at the hour the units are running, not on an empty board in the morning. A True-RMS clamp is written separately at the flat intake and at the output of the management board. If only one phase is low inside the flat and the management output is sound on three phases, the pile-up is the flat's distribution after the seal. If the same phase is low at the management output as well, a common bar or a riser screw has loosened. If all three phases are low in front of the meter, the matter is a BEDAŞ report. We do not open the meter seal, and we do not enter the transformer cubicle without a key.
The booster pump is three-phase, and on many new residences it is driven by a variable-speed drive. When one phase opens, the motor hums, the drive prints a fault code, and the management cuts the whole estate. The first job is not to change the motor. The three phases are read at the contactor output with a True-RMS clamp. If the missing phase is shown before the drive, the pump is not blamed. A loose terminal or a tripped breaker is written down. A Schneider or Siemens contactor is replaced with the series already standing on the board. The common compensation board does not stand in for a flat breaker. If a capacitor has swollen, a line is opened for the manager, and the flat neutral is not corrected from that board. Harmonic current from the drive and the lobby LEDs adds in the common neutral. If neutral current has passed the phase current, the neutral bar is tightened, and if the section is short the neutral conductor is enlarged. Enlarging the phase breaker hides this heat.
In residence kitchens there are flats where the induction hob, the dishwasher and the built-in oven were placed on one 16 ampere way. The living-room air conditioner leaves from that way as well. While the hob is running the unit cannot start, and the residual-current device or the breaker drops. The circuit is made dead, and where each conductor goes is written down. If the NYM section cannot carry the hob, the hob is given its own circuit. A branch whose section is enough stays in place, and only the phase is moved to a neighbour. A 32 ampere breaker is not fitted to a 2.5 mm² socket conductor. Lighting in 1.5 mm² is not taken above 16 amperes. An induction hob and an inverter split need a 30 mA Type A residual-current device. A Type AC unit can sit without tripping on that pulsating residual, or it can drop without a cause. If there is a bridge, the bridge comes out. A bridge leaves chassis leakage in the flat through the summer heat.
The hour is written on the measurement paper as well. A phase that looks sound at eight in the morning can sag at four. The note left with the manager goes with the reading taken while the units are on, not with an empty-hour reading. Which elevation is tied to which phase, which phase the booster sits on, and what the neutral amperes are stand on the same sheet. The flat owner does not have the common bar undone alone. The common bar belongs to the building. The side ahead of the sealed meter does not mix into this sheet. If the meter cover is warm and the seal is intact, the company line is a separate sentence, and the flat board is our sentence.

On the podium facing the marina the cafe, the market and the estate lobby breathe the same wet air. The socket terminal greens, the cover goes warm, and in the evening, when the espresso machine and the dishwasher draw together, the 30 mA device drops. The drop is not waved away as a sensitive device. The circuit is left dead, the green tail is cut back, and the colour and section of the remaining copper are written down. If humidity has lowered the insulation, the branch is separated with a 500 V megohmmeter. What is under one megaohm is not connected to a new breaker until it is renewed. If the commercial socket on the podium was added onto the residence riser above, it is separated. The residence neutral does not carry the cafe's steam machine. NYM stays in the dry flat. If the podium run is rotten, that piece is changed, and the plaster of the whole block is not broken for it. Salt does not pass by changing a cover. A new cover does not close a fire while a carbonised tail remains.
On most estates the podium cameras are plugged into the shop-window lighting socket. When a wet socket leaks, the recorder goes quiet as well and the corridor is blind at night. The camera supply is moved to its own breaker, and the lighting and the cafe socket are not tied to that breaker. The intercom transformer shares a multi-way socket with the lobby television. If the transformer has heated, the intercom is pulled onto its own thin pair, and a camera adapter is not added to that pair. A wet socket then drops neither the door speech nor the recording. RJ45 and coaxial ends are passed through a tester. A joint left because the picture was there goes dark a week later in the salt air. A duct is not opened to break the finished tile of the marina elevation. The existing shaft or halogen-free surface trunking is used.
A Beylikdüzü job enters by appointment. On the marina podium a burning smell, a socket that arcs and a shock are written at the head of the same day. The afternoon air-conditioning sag in summer is also taken into that day's measurement, because a morning reading does not show the fault. A minute is still not tied to the journey. The E-5 and the estate barrier produce a duration that cannot be held. Before setting off, the technician says on the phone that any tariff difference exists and that materials are separate. The management board and the flat board can be read on the same visit, and they need two separate approvals. The common screw is chosen with the manager. The phase distribution inside the flat is chosen with the owner.
The 2026 band is labour, materials sit outside it, and it moves on the podium. Fault finding is 750-1,500 TL, a breaker or a 30 mA Type A device 1,250-3,200 TL, a socket or a fitting 650-2,800 TL, a dedicated air-conditioning circuit 2,400-5,500 TL, a flat or lobby board 6,500-16,000 TL. Cutting a green terminal, reading a megohmmeter and writing the phases sit in the finding band. New NYM, a contactor and the device body are counted separately. The survey comes off the job if the repair is accepted. The binding figure is given after the timed reading is written and before a screwdriver turns. Workmanship is guaranteed for one year. The guarantee is for the terminal we tightened and the branch we pulled. Salt from the marina working into another socket the next year is not a guarantee of a circuit that was not measured. The side before the meter seal does not enter this figure.
The south-elevation units start within the same half hour, and if the induction hob was left on that phase the voltage sits down. The reading is taken with a True-RMS clamp, while the units are running, at the flat intake and at the management output. An empty board in the morning does not show this sag. If all three phases are low in front of the meter, the report goes to BEDAŞ.
Salt humidity rots the terminal. In the evening the espresso machine and the dishwasher draw together and the residual crosses the threshold. The device is not bridged. The green tail is cut back, the insulation is separated with a megohmmeter, and the commercial socket leaves the residence riser. A new cover does not finish the job while carbon remains. Protection goes back as 30 mA Type A.
The booster, the barrier, the lobby and the compensation are the management's common board. The hob, the sockets and the split unit are the flat owner's board. The common screw is chosen with the manager. The sealed meter belongs to BEDAŞ, and we do not open it. Both can be read on the same visit, and the approvals are written separately.
It does not. When a wet socket leaks, the recording goes quiet as well. The camera has its own breaker. The intercom leaves the lobby television and is put on its own thin pair. A camera adapter is not added to that pair. The ends are passed through a tester. Tile is not broken for the cable.
The items are labour. Finding a fault is 750-1,500 TL, a device or breaker 1,250-3,200 TL, a socket 650-2,800 TL, an air-conditioning circuit 2,400-5,500 TL, a board 6,500-16,000 TL. NYM and the contactor are excluded. The figure is written after the timed reading. There is no promised minute. Workmanship is one year and does not spread to a socket that was not measured.
Beylikdüzü on the European side is worked by appointment. A burning smell, arcing or a shock is moved ahead the same day; no minute is promised, because a time that cannot be held in bridge traffic helps nobody. A night or holiday difference is stated on the phone before departure.

A loose screw connection has carbonised the terminal. Take that outlet out of service at once; the point is found with a thermal camera without opening the wall.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
Branches are separated one by one at the board and the device reset; if it holds the fault is in the wiring, if not it is the device. The faulty leg is confirmed with a megohmmeter.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
If the building is dark, the record belongs to 186. If only the flat is dark, the fault is after the meter: one phase is missing or the neutral has broken. On neutral loss one phase climbs above 250 volts and another falls to 180.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
Inrush exceeds the existing circuit. The fix is not a bigger breaker but a dedicated run from the board with a motor characteristic device.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
The chandelier is fixed to the existing box and a load-rated hook. If the hook is not anchored in the slab, it is not hung. Live, neutral and earth are confirmed separately; the body is never put on phase.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
There is no protective earth and the neutral is bridged to the earth terminal in the socket. This is a lethal risk; stop using the appliance immediately.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceOn Beylikdüzü call-outs the team follows the sequence below. No arrival minute is promised. The technician's name is given on the phone before anyone sets off.
The bands below are the labour ranges actually seen on recent call-outs and exclude materials. The binding figure is given in writing after on-site measurement, and no work starts without approval.
| Job | Typical price range | What is included |
|---|---|---|
| Fault diagnosis and measured survey | 750 TRY – 1,500 TRY | Diagnosis with a True-RMS clamp, megohmmeter and thermal camera; the survey fee is deducted if the repair is accepted. |
| Breaker / RCD replacement | 1,250 TRY – 3,200 TRY | A 30 mA Type A device; varies with the number of ways and whether Schneider or Siemens is specified. |
| Dedicated air conditioning circuit | 2,400 TRY – 5,500 TRY | 3x2.5 or 3x4 mm² solid copper with a C20-C25 breaker; varies with run length and trunking route. |
| Flat board renewal (modular DIN) | 6,500 TRY – 16,000 TRY | Varies with room count, circuit splitting and whether a surge arrester is included. |
| Chandelier, spot and socket installation | 650 TRY – 2,800 TRY | Priced per unit; heavy chandeliers include a steel anchor set into structural concrete. |
| Internet and Cat6 data cabling | 1,100 TRY – 4,200 TRY | Includes a Cat6 run per room, an RJ45 data outlet and verification with a cable tester. |
| Factory / power factor periodic maintenance | 4,500 TRY – 18,000 TRY | By panel and step count; includes a thermal sweep and a written measurement report. |
Prices are estimated labour ranges and exclude materials. A binding quote is issued in writing after the technician measures on site and before any work begins. Last updated: October 2026.
Whatever we are called out for, before leaving we measure your board at five points and leave the result in writing. It is the cheapest way to see a developing fault before it stops anything.
All breaker and terminal temperatures under load with a FLIR thermal imager; every point above seventy degrees is recorded.
The 30 mA residual current device trip time measured in milliseconds with a dedicated tester.
Voltage between neutral and earth; more than a few volts indicates a loose neutral or a bootleg ground.
Earth resistance read with a digital earth tester and assessed against the 2 Ohm target.
Breaker ratings against conductor size; anything above a C16 on a 1.5 mm² run leaves the cable unprotected.
Fully stocked mobile vans: every vehicle carries Schneider and Siemens breakers, 30 mA Type A devices, surge arresters, solid copper cable drums and junction box sets, so most jobs finish on the same visit.
Service covers the neighborhoods of Istanbul's 39 districts. Not the whole of Turkey. A survey is not a binding quote.
10 / 10 · Residential neighborhoods sit first.
Google Review
Your review is how neighbours searching for an emergency electrician in your area find us. One tap opens the Google review page; there is no account to create and no form to fill in.
Current rating: 5.0 / 5.0 · 2 verified reviews
Leave 5★ On Google