November 2026 updated price and service guide

Districts

Arnavutköy

5.0 / 5.0 on Google · 2 verified reviews
  • On-call from Pendik · European side by appointment · no minute promise
  • State-Certified Mastery Qualification · Invoiced With A 1 Year Guarantee
  • No Surprise Charges · Clear Price Approval Before Work
  • TSE & ISO referenced materials · Scan slots on the certificates page

An electrician in Arnavutköy goes to two different jobs. One is the new housing around the airport: the fresh flat board toward Taşoluk and Hadımköy, a loose neutral and a balcony socket. The other is the loading-dock leveller, the shutter and the conveyor starter in a Hadımköy logistics warehouse. If a line stops in the warehouse, loading stops, and a stopped line costs the warehouse. The technician reads the panel, the contactor and the thermal overload. On the same visit the technician also looks at the coupling between the motor and the machine. If the coupling is spinning free, a new thermal does not make a stopped belt move. In the village house toward the north, toward Bolluca and Terkos, the job is different: a tired socket, a loose NYA, a water pipe used as an earth. A glass factory and a manufacturing line are not inside these three. The sealed meter belongs to BEDAŞ. The seal is not opened. The call is written in the appointment book. The airport road is not tied to a minute sentence.

  • Appointment, no minute promise
  • 38 Neighborhoods
  • 30 Services
Adnan Şemiye, ElektrikçiGO electrician, Istanbul building meter cabinet
Meter cabinet
Adnan Şemiye, ElektrikçiGO electrician, fitting an Istanbul meter cabinet

Founding master

Adnan Şemiye18 years in the field

MYK-certified master

Adnan Şemiye reads this job in the field. The price is written before work starts.

From the field

ElektrikçiGO emergency electrician van, Istanbul 24/7Emergency van · ⁦+90 582 403 10 87⁩

The new housing board around the airport

New Arnavutköy housing board, cover open, balcony socket on its own way

A loose neutral and a balcony socket in a Taşoluk flat

In a new block around the airport the board looks clean. A clean cover does not show that the neutral bar was tightened. If a screw was left half a turn short, the lamp flares under the evening load, the socket voltage wanders, and the caller asks for this as the mains. The reading is written at the flat intake: phase-to-neutral, phase-to-earth, neutral-to-earth. If neutral-to-earth is high and the neighbouring flat has the same flare, the riser neutral is chosen with the manager, because the line is the building's common property. If it wanders in one flat only, that flat's neutral screw is tightened. The side before the BEDAŞ seal is a separate line. We do not open the seal. In a new building the balcony socket is also left with its cover open and its gasket half done. Rain trips the fresh 30 mA device. The device is not bridged. The balcony circuit is separated from the indoor circuits and put on its own 30 mA Type A unit. The wet tail is cut. The clamp writes whether the air conditioner and the oven were piled on the same way. A 1.5 mm² conductor is not taken above 16 amperes. A new building does not justify a thin run. If the section is short the cable changes, and the ampere label is not inflated.

In a new flat every wet room has been piled onto one device. The bathroom, the balcony, the kitchen and sometimes the built-in appliances sit behind the same 30 mA unit. When one leaks, all of them go dark. Separating them is not upsizing the unit. The leaking way is read with a megohmmeter, and under one megaohm it is not connected back. A sound way stays as it is. If there is underfloor heating or a towel heater, that way is written separately. 'The new building is sound' is not said before that. A Schneider or Siemens enclosure is discussed in place of a site board whose cover will not close only after the loose neutral on the bar is tightened. Screwing a new brand onto a dirty or loose bar locks the flare inside. This housing job is not done with the warehouse contactor's parts. The warehouse stock is not carried into the flat. If it is carried, a thermal overload goes in place of the balcony socket and the flat still goes dark.

The meter boundary and the appointment in a new block

If a whole new residence goes dark at once, the flat neutral is not hunted. If the meter is cold, the report belongs to BEDAŞ. If the seal is sound and the cover is warm, the company line is opened and the flat board stays separate on the same paper. If one flat flares and the neighbour is calm, the screw belongs to that flat. The road around the airport does not squeeze this split into a minute. The call is written in the appointment book. The slot is said before setting off. A burning smell or a shock is moved forward in the book. Moving it forward is not quoting a time that cannot be held in the traffic of the airport road. On the phone the balcony socket's plug is pulled and the instruction is not to touch the board cover with a wet hand. A warehouse call is not squeezed into the same slot. If it is squeezed, the flat neutral and the leveller contactor go into the same bag and both stay half done.

In the new housing the labour stands on a separate line from the warehouse job. Standing apart is not doubling the price. The same 2026 band is written with a different fault line. Flat finding sits in the finding band. A separate 30 mA for the balcony sits in the device band. A socket sits in the socket band. An air-conditioning circuit has its own band. A board enclosure sits in the enclosure band. Figures are not announced before measurement. What is announced is the band itself: 750-1,500 TL finding, 1,250-3,200 TL a breaker or device, 650-2,800 TL a socket or light, 2,400-5,500 TL an air-conditioning circuit, 6,500-16,000 TL a board. Materials are excluded. The survey comes off the job if the repair is accepted. The binding figure is written before work. Workmanship is one year. That year does not contain a clause that shortens the airport road.

The Hadımköy warehouse, the coupling and the tired socket to the north

True-RMS clamp meter reading 12.47 A AC inside a live board

How the leveller, the shutter and the conveyor are read on the same visit

A stopped line in a Hadımköy warehouse is not a dark room in a house. If the hydraulic dock leveller does not rise, the lorry does not unload. If the shutter stops halfway, the door does not close. If the conveyor is silent, the carton stays where it is. All three cost the warehouse. The starter of all three is often in the same panel: a contactor, a thermal overload, sometimes a small drive. The panel is read first. Which motor's thermal has tripped, which coil does not pull, which contact is burnt, is written. The thermal is not turned above the nameplate current. If it is turned, a jammed shaft burns the winding and the line still stops. The three phases are read separately with the clamp. If one is missing, the cable or the contact is hunted, and the motor is not counted as replaced. If the coil voltage is low, the contactor chatters. Chatter also comes from the length of the warehouse run. Then the conversation is the section, not the thermal. Even if the contactor is Schneider or Siemens, what is read is not the brand. It is the coil and the contact mark. A glass furnace, a compensation panel and a workshop bench are not written onto this panel. If they are written, the warehouse is turned into a factory that is not there.

If the electrical side looks sound and the machine is stopped, the coupling is looked at. The look is on the same visit. It does not invent a second trade. If the motor shaft is turning and the conveyor belt is stopped, the coupling may be free, the key may have come out, or the belt may have dropped. The thermal does not trip then, because the motor spins unloaded. Fitting a new thermal does not make the belt move. If the leveller motor hums and the platform does not rise, the coupling or the hydraulic link is being forced. On a forced shaft the current goes above the nameplate and the thermal trips. Raising the thermal that tripped hides the jam. If the shutter stops halfway, the limit tail and the coupling are read separately. If the limit has opened, the motor forces all the way to the end. If the coupling has stripped, the motor turns and the shutter does not come down. They are not the same fault. The technician reads the panel, the contactor, the thermal and the coupling on the same visit. Turning the coupling's gear on a lathe is not this visit's claim. The claim is to separate an electrical stop from a mechanical disconnect and to write for the warehouse which part stopped. The cost of a stopped line comes from the wrong thermal. The right line shortens the cost. Shortening it is not a promised minute. The warehouse is in the appointment book. The slot is said before setting off.

The northern village house, BEDAŞ and a separate line of the same band

The house toward Bolluca and Terkos is neither the neutral of the new residence nor the conveyor of the warehouse. The socket cover is tired, it has yellowed, and the NYA tail is loose. A hot screw arcs, and the arc carbonises the Bakelite. The circuit is made dead, the carbonised tail is cut, and the remaining copper is read under load with a True-RMS clamp. A two-wire circuit has no earth. If a washing-machine body was bonded to a water pipe, the pipe is not counted as an earth. If there is a shock, the plug comes out. If there is no 30 mA Type A, the board work moves forward. This job is not mixed with the warehouse coupling. If it is mixed, a thermal overload is carried to the village socket and a socket cover is carried to the warehouse motor. Both are the wrong bag. At the appointment the address is asked: a Taşoluk flat, a Hadımköy warehouse, or a village house to the north. Three addresses are three slots. The airport road does not join these three slots in one time sentence. The BEDAŞ seal is not opened in any of the three. If the village is dark and the meter is cold, the report belongs to the company. If one socket is warm and the neighbour is lit, the side after the meter is ours.

The warehouse contactor and the village socket are two lines of the same price paper. They are not tied to the same invented minute fee. The 2026 band is labour excluding materials and is written after measurement. Fault finding is 750-1,500 TL, a contactor, a thermal or a residual-current device 1,250-3,200 TL, a socket or light 650-2,800 TL, an air-conditioning circuit 2,400-5,500 TL, a board 6,500-16,000 TL. Looking at the coupling does not invent a separate tariff. The look sits on the finding line of the same visit. Turning a gear on a lathe and overhauling a hydraulic pump are not inside this band, because that work is not this visit's claim. The NYY metre is measured inside the warehouse and is not buried inside the band. The survey comes off the job if the repair is accepted. The binding figure is on the paper before work starts. Workmanship is guaranteed for one year. Raising the thermal above the nameplate does not enter the guarantee. A minute is not inside this figure on the airport road or at the warehouse door.

Frequently asked

Frequently asked

What does a stopped line cost in a Hadımköy warehouse?

If the leveller does not rise the lorry does not unload, if the shutter stops halfway the door does not close, and if the conveyor is silent the carton stays. A stopped line costs the warehouse. The panel, the contactor and the thermal are read. The thermal is not turned above the nameplate. A glass factory and a compensation panel are not written. The call is an appointment, not a minute.

How are the contactor, the thermal and the coupling separated on the same visit?

If the motor spins unloaded and the belt is stopped, the coupling is free, the thermal does not trip, and a new thermal does not make the belt move. If the shaft is forced and the current goes above the nameplate, the thermal trips, the thermal is not raised, and the coupling or the jam is hunted. On a shutter the limit tail and the coupling are read separately. Turning a gear on a lathe is not this visit's claim. The split is written on the paper.

Why does a socket trip in a new Taşoluk flat?

The balcony socket gasket may be half done and the cover left open. Rain trips the fresh 30 mA device. The device is not bridged and the balcony circuit is separated. If the neutral screw is loose the lamp flares. The reading is written as phase-to-neutral, phase-to-earth, neutral-to-earth. If it is one flat, the screw is tightened. If the whole block is dark and the meter is cold, the report belongs to BEDAŞ.

What does a tired socket mean in a village house to the north?

Toward Bolluca and Terkos the cover has yellowed, the NYA tail is loose and the screw has heated. The tail is cut and the load is read with a True-RMS clamp. A water pipe is not counted as an earth. If there is no 30 mA Type A the board moves forward. This job is not the warehouse coupling. A thermal overload is not carried to the village socket. The appointment address is one of the three choices.

Is the 2026 Arnavutköy electrician price the same for the warehouse and the house?

The labour band is the same and the line is separate. Finding a fault is 750-1,500 TL, a contactor or device 1,250-3,200 TL, a socket 650-2,800 TL, an air-conditioning circuit 2,400-5,500 TL, a board 6,500-16,000 TL. Materials are excluded. Looking at the coupling does not open a separate tariff. The firm figure is written after measurement. Workmanship is one year. There is no minute on the airport road or at the warehouse door.

How is a night or Sunday call planned in Arnavutköy?

Arnavutköy on the European side is worked by appointment. A burning smell, arcing or a shock is moved ahead the same day; no minute is promised, because a time that cannot be held in bridge traffic helps nobody. A night or holiday difference is stated on the phone before departure.

Services

PLC programmingindustrial electrical serviceShort circuithome–plant electrical serviceSocket and switchhome electrical serviceResidual-current devicehome electrical serviceEarthinghome–plant electrical serviceCable and circuit runhome electrical serviceRewiringhome electrical serviceTelevision mountingelectrical fitting serviceAC Electrical Wiringresidential–commercial AC serviceIntercom & Doorbell Systemsresidential intercom serviceFuse & Panel Faultsconsumer unit & panel serviceChandelier Mounting & Lightingresidential lighting serviceInternet & Data Cablingresidential & office network serviceElectrical Fault Repair24/7 emergency fault serviceDistribution Board Setupresidential–commercial panel serviceEarthing & Lightning Protectionbuilding earthing & surge serviceSecurity Camera Systemssurveillance & CCTV serviceEV Charger InstallationEV charging infrastructure serviceSmart Home Automationsmart home & KNX/Zigbee serviceHalf The House Has No Powerpartial outage & phase loss repairBurning Smell and Crackling Socketsemergency thermal inspection & arc repairVoltage Fluctuation, Regulators and UPSvoltage protection & uninterruptible powerGenerator and ATS Paneltransfer panelMeter, Main Switch and Risercustomer side after the meterLift and Hydrophore Panelpanel supplySolar Inverter Board Connectioncustomer-side AC outputPanel faultLighting installationBreaker replacementSecurity camera

What Can You See At Home? Fast Diagnosis By Symptom

There is a burning smell from a socket

Single socket being checked for burn marks

A loose screw connection has carbonised the terminal. Take that outlet out of service at once; the point is found with a thermal camera without opening the wall.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

The breaker keeps tripping

Main switch and breaker row

Branches are separated one by one at the board and the device reset; if it holds the fault is in the wiring, if not it is the device. The faulty leg is confirmed with a megohmmeter.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

The flat has lost power

Meter measuring voltage

If the building is dark, the record belongs to 186. If only the flat is dark, the fault is after the meter: one phase is missing or the neutral has broken. On neutral loss one phase climbs above 250 volts and another falls to 180.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

The breaker trips when the AC or oven starts

Breaker dedicated to an appliance circuit

Inrush exceeds the existing circuit. The fix is not a bigger breaker but a dedicated run from the board with a motor characteristic device.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

A chandelier needs fitting

Chandelier on the ceiling

The chandelier is fixed to the existing box and a load-rated hook. If the hook is not anchored in the slab, it is not hung. Live, neutral and earth are confirmed separately; the body is never put on phase.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

I get a shock from the sink or washing machine

Washing machine socket connection

There is no protective earth and the neutral is bridged to the earth terminal in the socket. This is a lethal risk; stop using the appliance immediately.

Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.

Fix and price

How Our Field Team Works A Call

On Arnavutköy call-outs the team follows the sequence below. No arrival minute is promised. The technician's name is given on the phone before anyone sets off.

  1. 01
    Symptom
    The residual current device trips again the instant it is reset
    Measurement
    Branches are separated one by one at the board and each leg measured with a 500 V megohmmeter. Insulation resistance below 1 Megaohm shows that run's insulation is no longer doing its job.
    Intervention
    The faulty leg is isolated and the refrigerator, boiler and lighting restored within the first ten minutes. If damp is the cause the junction box is dried and encapsulated in dielectric gel; if the insulation is charred the run is renewed back to the board.
  2. 02
    Symptom
    A burning smell from a socket with a deformed face plate
    Measurement
    A FLIR thermal sweep is taken under load; where a loose screw connection has carbonised the terminal, that point reads between 160 and 200 degrees and is found without opening the wall.
    Intervention
    Blackened conductor ends are cut back to clean copper, the back-box replaced and the joint closed with a Wago 221 lever terminal. Every screw connection is tightened with a calibrated screwdriver to between 2.5 and 3.5 Nm.
  3. 03
    Symptom
    Half the flat has no power while the other half works
    Measurement
    Voltage is read phase by phase downstream of the meter. On neutral loss one phase measures above 250 volts and another around 180; that pattern burns appliance boards the same night.
    Intervention
    The main neutral terminals are opened, oxidised surfaces cleaned with dielectric solvent and torqued to specification. An over/undervoltage protection relay is added so appliances survive the next neutral loss.

2026 Electrician Prices and Recently Completed Jobs

The bands below are the labour ranges actually seen on recent call-outs and exclude materials. The binding figure is given in writing after on-site measurement, and no work starts without approval.

2026 Electrician Prices and Recently Completed Jobs
JobTypical price rangeWhat is included
Fault diagnosis and measured survey750 TRY – 1,500 TRYDiagnosis with a True-RMS clamp, megohmmeter and thermal camera; the survey fee is deducted if the repair is accepted.
Breaker / RCD replacement1,250 TRY – 3,200 TRYA 30 mA Type A device; varies with the number of ways and whether Schneider or Siemens is specified.
Dedicated air conditioning circuit2,400 TRY – 5,500 TRY3x2.5 or 3x4 mm² solid copper with a C20-C25 breaker; varies with run length and trunking route.
Flat board renewal (modular DIN)6,500 TRY – 16,000 TRYVaries with room count, circuit splitting and whether a surge arrester is included.
Chandelier, spot and socket installation650 TRY – 2,800 TRYPriced per unit; heavy chandeliers include a steel anchor set into structural concrete.
Internet and Cat6 data cabling1,100 TRY – 4,200 TRYIncludes a Cat6 run per room, an RJ45 data outlet and verification with a cable tester.
Factory / power factor periodic maintenance4,500 TRY – 18,000 TRYBy panel and step count; includes a thermal sweep and a written measurement report.

Prices are estimated labour ranges and exclude materials. A binding quote is issued in writing after the technician measures on site and before any work begins. Last updated: October 2026.

A Free Five-Point Board Safety Check On Every Call-Out

Whatever we are called out for, before leaving we measure your board at five points and leave the result in writing. It is the cheapest way to see a developing fault before it stops anything.

01

All breaker and terminal temperatures under load with a FLIR thermal imager; every point above seventy degrees is recorded.

02

The 30 mA residual current device trip time measured in milliseconds with a dedicated tester.

03

Voltage between neutral and earth; more than a few volts indicates a loose neutral or a bootleg ground.

04

Earth resistance read with a digital earth tester and assessed against the 2 Ohm target.

05

Breaker ratings against conductor size; anything above a C16 on a 1.5 mm² run leaves the cable unprotected.

Fully stocked mobile vans: every vehicle carries Schneider and Siemens breakers, 30 mA Type A devices, surge arresters, solid copper cable drums and junction box sets, so most jobs finish on the same visit.

Services We Provide In This Area

Neighborhoods

Service covers the neighborhoods of Istanbul's 39 districts. Not the whole of Turkey. A survey is not a binding quote.

Show neighborhoods

38 / 38 · Residential neighborhoods sit first.

Google Review

Happy With The Work? Leave Us 5★ On Google

Your review is how neighbours searching for an emergency electrician in your area find us. One tap opens the Google review page; there is no account to create and no form to fill in.

Current rating: 5.0 / 5.0 · 2 verified reviews

Leave 5★ On Google
QR code opening the ElektrikçiGO Google review page
Scan with your phone after the job