
Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
November 2026 updated price and service guide
Districts
Ümraniye 24/7 emergency electrician. We respond without a minute promise to midnight breaker tripping, residual current device faults, burnt sockets and consumer unit failures. Certified technicians across Dudullu, Şerifali, Yamanevler, Çakmak, İnkılap, Atakent, Ihlamurkuyu, Finanskent, Esenkent and Hekimbaşı, faults proven by True-RMS measurement, written price approval and an official 1 year workmanship guarantee.


Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
From the field
Emergency van · +90 582 403 10 87
In the İMES and DES industrial estates of Dudullu and Şerifali, forklift battery chargers run all night. These rectifier-based loads inject heavy harmonics into the supply and stress the power capacitors in the compensation panel. Capacitors bulge, the step contactor tips weld together under inrush and a burning odour fills the enclosure.
Our crew secures the supply with a lockout/tagout kit, discharges the capacitors and fits a dedicated capacitor-switching contactor with discharge resistors. Total harmonic distortion is measured with an analyser and a detuned reactor recommended where the ratio is high. The charging station circuit is separated from workshop lighting and fed by its own NYY cable from the board.
In the five-storey apartment stock of Yamanevler, Çakmak, İnkılap and Ihlamurkuyu, the kitchen branch runs off a single 16 A breaker. When the built-in oven, dishwasher and water heater work together in the evening the circuit saturates; the breaker trips thermally or the terminal inside the socket box blackens. The hall cupboard board usually protects the whole flat with one 30 mA device, so a single kitchen fault blacks out the entire home.
The repair measures the kitchen loads and splits the circuit: a separate C16 for the oven, another for the dishwasher and a 3x4 mm² run on a C20 for the water heater. The board is upgraded to a modular DIN-rail enclosure with lighting, sockets and wet rooms on separate devices. A fault then isolates only its own leg instead of the whole flat.

In the newer complexes toward Finanskent, Esenkent and Parseller, the load per flat has risen sharply over the years with air conditioning, tumble dryers and electric vehicle charging. The shared riser feeding the floors from the meter panel was never dimensioned for that demand, so it heats up in the evening; carbonisation starts at the busbar terminals and voltage sags on the upper floors.
Voltage and current are measured under load at the riser head and the flat intake, and busbar temperatures swept with a FLIR thermal imager. Carbonised terminals are renewed with fire-rated ceramic blocks and torqued to specification. Where voltage drop exceeds five percent, an upgrade of the riser to 4x25 mm² NYY cable is presented to the management with the measurement report.
The most frequent night call in Ümraniye is a residual current device that trips again the instant it is reset. The technician disconnects every branch at the board and resets the device; if it holds, the fault is in the installation. Branches are energised one at a time until the faulty leg is confirmed. Because no drill or breaker is used at night in terraced blocks, location is done silently with a FLIR thermal imager and a cable tracer.
Once the faulty leg is isolated, the refrigerator, boiler and lighting are restored within the first ten minutes. A dead boiler on a winter night is a serious risk in households with children or elderly residents, so the boiler is afterwards always moved to a dedicated circuit. Noisy chasing and breaking work is booked for the next working day and the temporary line left safely inside fire-retardant trunking.

At the end of every job the circuit is measured with a 500 V megohmmeter; if phase-to-earth insulation resistance falls below 1 Megaohm the cable is pulled anew rather than patched. Earth loop impedance is measured at socket outlets to prove the protective device clears a fault inside TS IEC 60364 disconnection limits. During testing phase, neutral and earth are read separately, and any voltage between neutral and earth triggers a search for a bootleg ground jumper.
Earth electrode resistance is measured with a digital earth tester; when the 2 Ohm target is missed an additional rod is driven or bentonite backfill applied. Every recorded value is written numerically onto the service report, handed to the customer and kept on file, so readings can be compared at the next inspection.
If a sharp Bakelite odour or smoke comes from the board and it is not yet in flames, trip the main switch using a dry wooden handle. Never pour water onto switchgear or a burning cable; water conducts, intensifies the arc flash and electrocutes the person intervening. Use only a Class ABC dry chemical powder or carbon dioxide extinguisher.
Never grab an electrocuted person bare-handed; the current passes into the rescuer too and leaves two people across the circuit. Separate the casualty from the source with a dry broom handle, a leather belt or a wooden chair, call the emergency ambulance number, then alert our 24/7 emergency electrician line. Even if the casualty is conscious and says they feel fine they must still attend hospital, because current that has crossed the torso can produce a cardiac rhythm disturbance hours later. Once power is off the board cover is closed and nobody attempts to reset the lever until the electrician arrives.

At a metalworking shop in Dudullu, a bang and heavy smoke from the compensation panel were reported at 02:20. Our crew reached the address in twenty-eight minutes. With the supply secured by a lockout/tagout kit, the third step power capacitor was found split open and the step contactor tips welded together. Harmonic analysis showed fifth order content at twenty-nine percent, injected by the forklift chargers. The ruptured capacitor and welded contactor were removed and replaced with a discharge-resistor capacitor contactor and a harmonic-rated capacitor. The reactive power controller was re-set and the panel handed over after a thermal sweep under load.
At the end of the callout line insulation resistance was re-measured with a megohmmeter, the values entered on the technical service report and a copy left with the customer. Fitted components carry both the manufacturer warranty and our 1 year labour guarantee.
With dispatch coordinated from our Pendik hub and GPS-tracked vans patrolling the main Ümraniye corridors, average arrival is no fixed minutes. When the technician departs, their name, vehicle plate and a live tracking link are sent by SMS or WhatsApp.
Yes. We measure the capacitance of each step in the compensation panel, identify bulged capacitors that have lost capacity, inspect the contactor tips and re-tune the reactive power controller. Where harmonic sources such as forklift chargers or variable frequency drives are present, total harmonic distortion is measured and harmonic-rated capacitors with a detuned reactor recommended if required. Measured values are delivered as a written report.
In these flats the kitchen runs off a single 16 A breaker with three large appliances stacked on one leg. Enlarging the breaker leaves the cable unprotected and creates a fire risk. The correct fix is splitting the circuit: a separate C16 for the oven, another for the dishwasher and a 3x4 mm² run on a C20 for the water heater. The existing conductor size is physically measured and the breaker rating chosen to match.
Every part replacement, circuit run and board overhaul carries our official 1 year workmanship guarantee. We install only TSE and VDE certified Schneider, Siemens, ABB, Legrand, Wago and HES Kablo products; copper-clad aluminium cable and uncertified breakers are never fitted.
Every mobile unit is a travelling electrical workshop: Type B and C breakers, 30 mA and 300 mA residual current devices, Type 2 surge arresters, Wago terminal ranges, NYM, NYA and NYY cable drums plus IP54 and IP65 socket mechanisms are carried on board. Thanks to that stock the fault is usually cleared permanently on the same visit.
Yes. Ümraniye is covered on Saturday, Sunday, public holidays and at night. On the Anatolian side the on-call run starts from Pendik. Arrival depends on traffic and the queue; no minute is promised. A night or holiday difference is stated on the phone before anyone sets off.

A loose screw connection has carbonised the terminal. Take that outlet out of service at once; the point is found with a thermal camera without opening the wall.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
Branches are separated one by one at the board and the device reset; if it holds the fault is in the wiring, if not it is the device. The faulty leg is confirmed with a megohmmeter.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
If the building is dark, the record belongs to 186. If only the flat is dark, the fault is after the meter: one phase is missing or the neutral has broken. On neutral loss one phase climbs above 250 volts and another falls to 180.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
Inrush exceeds the existing circuit. The fix is not a bigger breaker but a dedicated run from the board with a motor characteristic device.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
The chandelier is fixed to the existing box and a load-rated hook. If the hook is not anchored in the slab, it is not hung. Live, neutral and earth are confirmed separately; the body is never put on phase.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and price
There is no protective earth and the neutral is bridged to the earth terminal in the socket. This is a lethal risk; stop using the appliance immediately.
Diagnosis sits in the 750–1,500 TL band. The job line is written from the 2026 table after measurement.
Fix and priceOn Ümraniye call-outs the team follows the sequence below. No arrival minute is promised. The technician's name is given on the phone before anyone sets off.
The bands below are the labour ranges actually seen on recent call-outs and exclude materials. The binding figure is given in writing after on-site measurement, and no work starts without approval.
| Job | Typical price range | What is included |
|---|---|---|
| Fault diagnosis and measured survey | 750 TRY – 1,500 TRY | Diagnosis with a True-RMS clamp, megohmmeter and thermal camera; the survey fee is deducted if the repair is accepted. |
| Breaker / RCD replacement | 1,250 TRY – 3,200 TRY | A 30 mA Type A device; varies with the number of ways and whether Schneider or Siemens is specified. |
| Dedicated air conditioning circuit | 2,400 TRY – 5,500 TRY | 3x2.5 or 3x4 mm² solid copper with a C20-C25 breaker; varies with run length and trunking route. |
| Flat board renewal (modular DIN) | 6,500 TRY – 16,000 TRY | Varies with room count, circuit splitting and whether a surge arrester is included. |
| Chandelier, spot and socket installation | 650 TRY – 2,800 TRY | Priced per unit; heavy chandeliers include a steel anchor set into structural concrete. |
| Internet and Cat6 data cabling | 1,100 TRY – 4,200 TRY | Includes a Cat6 run per room, an RJ45 data outlet and verification with a cable tester. |
| Factory / power factor periodic maintenance | 4,500 TRY – 18,000 TRY | By panel and step count; includes a thermal sweep and a written measurement report. |
Prices are estimated labour ranges and exclude materials. A binding quote is issued in writing after the technician measures on site and before any work begins. Last updated: October 2026.
Dudullu
Workshop compensation capacitor
Yamanevler
Kitchen split onto three breakers
Çakmak
Stair timer and sensor renewal
Esenkent
Riser terminal carbonisation repair
Whatever we are called out for, before leaving we measure your board at five points and leave the result in writing. It is the cheapest way to see a developing fault before it stops anything.
All breaker and terminal temperatures under load with a FLIR thermal imager; every point above seventy degrees is recorded.
The 30 mA residual current device trip time measured in milliseconds with a dedicated tester.
Voltage between neutral and earth; more than a few volts indicates a loose neutral or a bootleg ground.
Earth resistance read with a digital earth tester and assessed against the 2 Ohm target.
Breaker ratings against conductor size; anything above a C16 on a 1.5 mm² run leaves the cable unprotected.
Fully stocked mobile vans: every vehicle carries Schneider and Siemens breakers, 30 mA Type A devices, surge arresters, solid copper cable drums and junction box sets, so most jobs finish on the same visit.
Service covers the neighborhoods of Istanbul's 39 districts. Not the whole of Turkey. A survey is not a binding quote.
35 / 35 · Residential neighborhoods sit first.
Google Review
Your review is how neighbours searching for an emergency electrician in your area find us. One tap opens the Google review page; there is no account to create and no form to fill in.
Current rating: 5.0 / 5.0 · 2 verified reviews
Leave 5★ On Google