Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
Kartal district
Atalar 24/7 emergency electrician. In this Kartal neighbourhood we respond without a minute promise to midnight breaker tripping, residual current device faults, burnt sockets and consumer unit failures. In apartment and complex stock, saturated kitchen circuits, bathroom water heater runs and riser overheating are measured on site. Certified technicians, faults proven with a True-RMS clamp meter and a megohmmeter, written price approval and an official 1 year workmanship guarantee.


Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
From the field
Emergency van · +90 582 403 10 87
In 1980s and 1990s apartment buildings across Atalar, interior electrical networks were routed through narrow-diameter iron or rigid PVC Bergman conduits. Decades of continuous thermal cycling dry out and embrittle the PVC insulation on single-core NYA conductors. When built-in kitchen ovens or electric kettles run, elevated conductor temperatures cause phase and neutral wires to melt and fuse together against the inner conduit walls. Attempting to pull replacement wires using standard fish tapes becomes impossible as stuck wires snap inside the masonry. On site, I pinpoint the fault using a digital insulation tester. Rather than demolishing decorative wall plaster, I route heavy-duty 3x2.5 mm² and 3x4 mm² flame-retardant NYM antigron conductors neatly above skirting boards inside screw-anchored V0 fire-rated PVC trunking. I subdivide kitchen circuits onto dedicated Type B and C 16 A Schneider breakers in the consumer unit. Surface trunking circuit installation and rewiring labor is between 1,400 and 2,800 TRY.
Connecting a 3,000W built-in oven and a dishwasher to a single shared vintage junction box chars internal terminal blocks, releasing acrid burning fumes. I open ceiling boxes, excising scorched joints and re-terminating with genuine flame-retardant Wago 221 lever connectors, installing ceramic-backed 16 A grounded sockets behind appliances. Kitchen junction box overhaul and appliance outlet mounting labor is between 1,200 and 2,400 TRY.
In older Atalar apartments lacking structural earth wiring, handymen bridged neutral to earth pins inside wall sockets (bootleg grounding). If the street neutral opens, full 230V live mains voltage electrifies refrigerator and washing machine metal casings, creating lethal shock hazards. I open all socket outlets, severing illegal bootleg jumpers, pull a dedicated 16 mm² solid copper earthing conductor from the building ground electrode, and distribute continuous yellow-green 2.5 mm² earth leads to every outlet. Bootleg ground elimination and dedicated earthing circuit installation labor is between 1,500 and 3,500 TRY.
In winter, 2,500W infrared heaters running in living rooms and bedrooms overheat twisted joints inside ceiling junction boxes, leaving black scorch marks on walls. I access junction boxes, cutting away fatigued splices to re-terminate with genuine fireproof Wago 221 lever connectors, pulling dedicated 3x2.5 mm² antigron lines to heater outlets. Space heater circuit reinforcement and junction overhaul labor is between 1,200 and 2,400 TRY.

In older Atalar fuse boards, wrapping copper wire around blown ceramic fuse cartridges prevents short-circuit clearance, igniting in-wall structural fires. I completely dismantle obsolete porcelain fuse boxes, installing modern flame-retardant DIN-rail modular consumer units. I install calibrated Schneider or Siemens MCBs (Type B10 for lighting, Type B16/C16 for sockets) protected by a certified 40 A 30 mA life-safety RCD. Full apartment consumer unit modernization labor is between 3,500 and 7,500 TRY.
To isolate moisture-induced leakage on bathroom instantaneous water heaters and washing machine circuits, I install a dedicated 16 A/32 A 10 mA ultra-sensitive compact RCBO on the bathroom branch. If a wet-zone earth fault occurs, the rest of the residence remains fully powered. Bathroom RCBO installation labor is between 1,200 and 2,400 TRY.
To protect bathroom junction boxes from steamy condensation in vintage buildings, I encapsulate terminal blocks inside IP68 gel-filled enclosures and upgrade sockets to IP44 spring-lid units. Bathroom moisture waterproofing and socket renewal labor is between 1,000 and 2,000 TRY.
Grid switching transients and storm-induced overvoltage spikes destroy refrigerator compressor electronics and combi boiler PCBs. I install DIN-rail Type 2 Surge Protective Devices directly downstream of the main breaker, bonding earth leads with a 6 mm² solid copper conductor to the ground busbar. Type 2 SPD surge arrester installation labor is between 1,200 and 2,200 TRY.
An integrated V-Protector digital voltage monitoring relay disconnects mains power within milliseconds whenever line voltage surges past 260V or sags below 170V, protecting sensitive domestic electronics. Digital voltage relay installation and calibration labor is between 1,200 and 2,400 TRY.
In Atalar apartments with enclosed balconies, the combi boiler feed is isolated from general sockets onto an adjacent double-pole 2A/6A fused spur, fed by an unbroken 3x2.5 mm² line from the board. Boiler dedicated switch and circuit installation labor is between 1,200 and 2,400 TRY.
In summer, compressor inrush currents from air conditioners in living rooms and bedrooms trip fatigued Type B 16 A breakers. I pull a dedicated 3x4 mm² antigron line from the panel, installing a Type C 20A Schneider breaker. AC dedicated circuit installation labor is between 1,400 and 2,800 TRY.

When an emergency call arrives from Atalar, thorough familiarity with neighborhood street layouts ensures prompt arrival at your door. The immediate priority is isolating smoking outlets or jammed main breakers at the panel, safely restoring power within 15 minutes. I dispatch fully equipped with digital True-RMS instruments, genuine Schneider/Siemens breakers, and fire-rated wiring. Estimated labor ranges are confirmed by phone and finalized on site after diagnostics.
On site, I first measure socket earth continuity and phase balance with digital instruments, demonstrating dangerous bootleg jumpers to the client before prompt rectification. Emergency diagnostic inspection and initial safety isolation labor across Atalar residences is between 800 and 1,500 TRY.
Upon completing repairs, I measure voltage stability, earth loop continuity, and RCD trip speed across all outlets, documenting all readings on the signed service sheet. All installed parts and labor carry a full warranty. An official corporate e-invoice is delivered immediately upon completion.
I provide Atalar homeowners and building managers with written technical service sheets complete with updated panel circuit diagrams and breaker labels. Premium materials and correct conductor sizing permanently eliminate electrical fire and outage risks across the neighborhood.
In vintage Atalar apartment blocks, I inspect service entrance kofra neutral blocks and NH blade fuses using thermal cameras, upgrading overheated blocks with ceramic assemblies to prevent 380V overvoltages. Main service kofra thermal inspection and overhaul labor is between 1,500 and 3,000 TRY.
The kitchen circuit overloads old 2.5 mm² wiring inside narrow Bergman conduits. I resolve this by pulling a dedicated flame-retardant line inside baseboard trunking, solving overheating and odors permanently.
If narrow-gauge iron conduits are blocked, rather than breaking walls, I route lines neatly above skirting boards inside decorative flame-retardant PVC trunking.
Within approximately 2 hours, I dismantle the old box, installing a fire-rated modular enclosure with Schneider MCBs and a certified 30 mA RCD to secure the home.
Yes. I respond 24/7 on emergency duty for night breaker trips, smoke, burning smells, and sudden power failures. Emergency rates are confirmed upfront by phone with prompt arrival.
The socket lacks an earth line or has a bootleg neutral jumper. I remove the jumper and pull a dedicated line from the main building earth electrode to eliminate shock hazards.
Yes. All installed genuine Schneider/Siemens parts and labor carry a comprehensive guarantee, with corporate e-invoices issued via email upon completion.
I arrive promptly across all Atalar streets via the Marmaray corridor in a fully outfitted vehicle, diagnosing faults with locked transparent pricing confirmed before beginning work.
Immediately drop main disconnects and call an emergency electrician. I replace overheated NH blade fuses and neutral terminals with ceramic blocks to safely restore power and protect flats.
Initial safety triage is conducted by phone, advising you to isolate main switches if smoke or arcing occurs. The electrician dispatches promptly with confirmed transparent pricing.
Within approximately 2 hours, I dismantle the vintage ceramic fuse box, installing a fire-rated modular enclosure with Schneider MCBs and a certified 30 mA RCD, securely labeling and torquing all circuits.
I pull a dedicated 3x2.5 mm² or 3x4 mm² NYM run inside decorative baseboard trunking from the panel, installing a ceramic-backed 16 A outlet behind the oven for total fire safety.
In Atalar we handle everything on the customer side of the meter: breaker tripping and residual current device faults, burnt sockets and terminals, board renewal and breaker replacement, earthing installation with resistance testing, lighting and chandelier mounting, dedicated circuits for boilers and air conditioning, and surge arresters. Measurement uses a True-RMS clamp meter, a megohmmeter and a FLIR thermal imager.
In most cases no. The fault is first narrowed down branch by branch at the board, then pinpointed with a FLIR thermal imager and an inductive cable tracer, so no needless breaking is done. Where leakage is in an underground or under-screed run, a cable fault locator usually narrows it to within a metre and only that area is opened. If breaking is unavoidable it is reported in writing and approved first.
Service covers the neighborhoods of Istanbul's 39 districts. Not the whole of Turkey. A survey is not a binding quote.
Atalar, Kartal. The map is centered on the neighborhood. Arrival changes with the hour and the traffic.