Adnan Şemiye reads this job in the field. The price is written before work starts.
Ataşehir district
Aşık Veysel 24/7 emergency electrician. In this Ataşehir neighbourhood we respond without a minute promise to midnight breaker tripping, residual current device faults, burnt sockets and consumer unit failures. In apartment and complex stock, saturated kitchen circuits, bathroom water heater runs and riser overheating are measured on site. Certified technicians, faults proven with a True-RMS clamp meter and a megohmmeter, written price approval and an official 1 year workmanship guarantee.


Founding master
Adnan Şemiye18 years in the field
MYK-certified master
Adnan Şemiye reads this job in the field. The price is written before work starts.
From the field
Emergency van · +90 582 403 10 87
In older residences across Aşık Veysel neighborhood, the most urgent complaint is feeling tingling electric shocks when touching a washing machine barefoot on bathroom tiles, or experiencing buzzing shocks across fingertips when touching the stainless steel kitchen sink. This symptom confirms bootleg grounding behind wall receptacles. Because the operational neutral is bridged directly onto the earth pin, the nominal 10–30V voltage drop existing along active neutral returns during appliance operation is applied directly onto appliance chassis surfaces. Wet bathroom floors drastically lower skin resistance, transforming this potential into painful electric shocks.
Far more lethal is an upstream open-neutral fault. When the neutral connection loosens or breaks at the utility street pillar or building main busbar, the bootlegged earth pin loses its return path and energizes directly to full 230V phase potential through internal appliance resistances. The washing machine's entire metal exterior becomes fully live with lethal mains voltage. Because bootleg jumpers prevent RCD operation, no safety breaker can trip. This constitutes an immediate life-safety emergency requiring urgent response from our emergency electrician team.
Appliance chassis leakages not only present direct touch electrocution hazards, but they also subject sensitive microcontroller boards within combi boilers, dishwashers, and water heaters to continuous reverse ground potentials, causing component burnouts. Stray currents propagating across metallic water pipe networks can energize metal plumbing across adjacent apartments, turning the entire building's piping live. Consequently, bootleg grounding must never be tolerated as a substitute for true earthing.
Biologically, the human body is critically sensitive to 50Hz alternating currents. In wet bathroom environments, total body impedance plunges toward 1000 Ohms. A 230V potential touching skin drives $220 ext{ mA}$ ($0.22 ext{ Amps}$) through cardiac pathways. This current is more than seven times the fatal ventricular fibrillation threshold of $30 ext{ mA}$, causing cardiac arrest within seconds. This medical and physical reality demonstrates why bootleg grounding must be eradicated without delay.
In properties with bootleg grounding, any reverse polarity wiring error where live and neutral conductors are inverted immediately connects full live mains voltage directly to the earth terminal, transforming every plugged-in appliance chassis into an instant lethal hazard.
Our technical intervention begins by methodically opening every single socket box across the apartment. All neutral-to-earth bootleg wire links are severed and permanently removed. Using flexible steel draw springs, dedicated 2.5mm² standard green-yellow H07V-U or H07V-K protective earth conductors are drawn from junction boxes directly into each outlet. These earth wires terminate onto a solid brass earthing busbar within the consumer unit. Neutral and protective earth busbars are completely isolated from each other, strictly separating operating neutral currents from protective ground safety paths.
During earthing cable installation, old splices within junction boxes are thoroughly inspected. Earth conductors are never joined with vinyl tape inside boxes; they are secured using dedicated spring Wago connectors or solid brass earthing terminal blocks. Earth prong spring tension and contact resistance are validated at every socket using digital socket polarity testers, verifying phase-neutral 230V, phase-earth 230V, and neutral-earth near 0V.
A Main Equipotential Bonding (MEB) bar is installed, bonding incoming metallic domestic water pipes, heating manifolds, and gas pipe networks to the primary earthing busbar via heavy 6mm² or 10mm² green-yellow conductors. This eliminates any possibility of static or dynamic stray voltage accumulating on building plumbing fixtures.
Gas pipelines must strictly never be utilized as earth electrodes. In certain vintage properties, grounding wires are found clamped onto gas supply pipes; this presents an extreme catastrophe hazard, where any electrical spark during gas seepage can cause catastrophic explosions. Such illegal bonds are disconnected immediately and transferred onto independent copper ground rods.
During electrical rehabilitation, damaged or undersized backboxes are replaced with certified deep-profile flame-retardant enclosures, ensuring conductors sit comfortably with optimal thermal ventilation.

Once bootleg jumpers are eliminated and genuine earth lines are installed, a 30 mA residual current device is fitted into the consumer unit. The human heart experiences fatal ventricular fibrillation at currents exceeding 30 milliamperes (0.03A). A 30 mA RCD measures the differential between outgoing phase current and returning neutral current, cutting power within 30 milliseconds the moment a 30 mA imbalance occurs. Following installation, calibrated RCD testers verify actual trip current (mA) and trip time (ms) to guarantee certified performance.
To achieve compliant ground impedance, a 1.5-meter solid copper earth electrode is driven into the building ground and connected to the main service panel using heavy 1x16mm² NYA protective bonding conductor. Earth ground resistance is measured with digital megohmmeters to ensure levels below 2 Ohms. When seeking a licensed electrician to protect your family's safety, we provide certified electrical engineering services.
Another frequent danger in older buildings is accidental physical contact between neutral and earthing busbars inside the main distribution board. In our overhaul, the main board is disassembled and the neutral busbar is isolated onto reinforced standoff insulators. Every individual branch circuit is megger-tested to eliminate latent neutral-to-earth leakages, completely preventing nuisance RCD tripping.
Bathroom wet-zone standards (Zone 0 and Zone 1) are rigorously implemented. Direct 230V outlets and light switches are prohibited within shower cubicle splash zones; only IPX4/IPX5 rated luminaires and SELV 12V isolated safety transformer systems are permitted.
During socket earthing continuity testing, loop impedance is verified across all rooms to guarantee that circuit breakers clear downstream short circuits instantaneously.

Throughout Aşık Veysel neighborhood, we service 3004th Avenue, Aşık Veysel Park area, and all residential side streets with mobile service units. All bootleg removals, grounding installations, and RCD retrofits are tested and signed off with written guarantees.
All RCDs, earthing rods, and copper conductors deployed in our services are genuine TSE and VDE certified products. For life-threatening bootleg grounding faults, our emergency rapid response team arrives immediately without scheduling delays.
Across all wet-zone sockets in kitchens and bathrooms, grounding loop impedance and insulation resistance are certified using calibrated Fluke and Chauvin Arnoux diagnostic instruments, providing clients with documented electrical safety validation.
When retrofitting protective earthing into older apartment blocks, architectural surface trunking is neatly concealed along baseboard profiles, preserving existing paintwork, plaster, and bathroom tiles flawlessly.
If a short jumper wire is visible connecting the neutral terminal to the earth prong when opening the socket faceplate, or if metal appliances produce tingling shocks, bootleg grounding is present.
When neutral breaks, it loses zero reference and carries full 220V phase voltage through appliance windings. The bootleg jumper directs this lethal 220V directly onto the external metal casing.
RCDs monitor current balance between outgoing phase and returning neutral conductors. Current circulating through bootleg jumpers causes a differential mismatch that trips the RCD instantly.
Yes. A solid copper earthing rod is driven into the ground, connected to the main panel with 16mm² wire, and dedicated green-yellow protective conductors are routed to individual flats via conduits or risers.
In a typical 2-bedroom or 3-bedroom apartment, opening all sockets, removing jumpers, pulling earth lines, and installing the RCD is completed within 3–5 hours.
Ground resistance is verified with calibrated digital earth megohmmeters. For residential installations, achieving earth loop impedance below 2 Ohms is the mandatory international safety benchmark.
No. An RCD cannot operate with bootleg jumpers in place; it will trip instantaneously whenever any appliance is connected. All bootleg links must be removed before energizing.
When older galvanized metal pipes are partially replaced with plastic PPRC plumbing, earth continuity is broken. Appliance leakage can energize all taps, faucets, and running shower water across the building.
In Aşık Veysel we handle everything on the customer side of the meter: breaker tripping and residual current device faults, burnt sockets and terminals, board renewal and breaker replacement, earthing installation with resistance testing, lighting and chandelier mounting, dedicated circuits for boilers and air conditioning, and surge arresters. Measurement uses a True-RMS clamp meter, a megohmmeter and a FLIR thermal imager.
In most cases no. The fault is first narrowed down branch by branch at the board, then pinpointed with a FLIR thermal imager and an inductive cable tracer, so no needless breaking is done. Where leakage is in an underground or under-screed run, a cable fault locator usually narrows it to within a metre and only that area is opened. If breaking is unavoidable it is reported in writing and approved first.
Service covers the neighborhoods of Istanbul's 39 districts. Not the whole of Turkey. A survey is not a binding quote.
Aşık Veysel, Ataşehir. The map is centered on the neighborhood. Arrival changes with the hour and the traffic.